background image

Operation Guide

Indication module registration (i95 and i95 ECO)

You may  register  the  indication  module  (sold  separately) to  make
operation  of  the  immobilizer  more  convenient.  To  do  that,  switch
the immobilizer to the device registration mode. Then, perform the
following actions:
1) Connect power to the indication module.
2) Wait until the connection monitoring is over (10 seconds before

the LED stops blinking).

3) Press  and  hold  the  indication  module  button  for  at  least  3

seconds, then release it.

4) If the indication module has been registered successfully, you

will see the LED flash in green. In case of a registration error
(i.e.,  if  there  is  no  locking  module  in  the  device  registration
mode), the LED will flash in red.

5) Turn off the ignition to exit the device registration mode.

The immobilizer only supports one indication module.

53

Module button

Registration 
confirmation

Module power supply

Re-energize the indication module

Module LED

Locking module

N times

In device registration mode

Audible signal

> 3 sec

Blinks 

for 10 sec

Once

Once

Содержание i95

Страница 1: ...i95LUX i95 i95ECO immobilizer We wish you safe and enjoyable riding Revision 1 July 2014 StarLine s Federal Support Service Toll free Russia 8 800 333 80 30 Ukraine 8 800 502 308 Kazakhstan 8 800 070...

Страница 2: ...1 Operation modes 23 Protection modes 25 Additional modes 26 Door lock control 28 Hood lock control 30 Starting to move 32 Engine locking expected alert 32 Label battery low alarm 33 Connection check...

Страница 3: ...ice registration 48 Entering the device registration mode on i95 LUX 48 Entering the device registration mode on i95 or i95 ECO 50 Label registration 52 Indication module registration i95 and i95 ECO...

Страница 4: ...r to ensure safe operation of the immobilizer 1 Using a vehicle with an immobilizer installed requires you to Have a label at hand Know the unlock code If all labels and the unlock code are not availa...

Страница 5: ...ially when moving at high speeds 3 If you hear a label battery low alarm replace the battery in time We recommend having a spare battery in the vehicle stored in its original package 4 The immobilizer...

Страница 6: ...he LED blinks once the label is out of coverage Protection functions are off in the service mode Anti theft mode Service mode Label successfully recognized 1 audible signal Label not available Enter u...

Страница 7: ...95 LUX i95 i95 ECO Installation Guide Operation Guide Plastic card Label with battery 2 pcs Locking module Indication module Audible alarm unit Function i95 LUX i95 i95 ECO Central lock control Hands...

Страница 8: ...Unlock code Allows using the vehicle in case the battery discharges or all labels are lost The unlock code is hidden under a scratch off strip CAUTION Don t tell your unlock code to anyone Remember th...

Страница 9: ...tion sensor The immobilizer s built in motion sensor allows for simultaneous reliable protection of a parked vehicle and a remote start of its engine Door and hood locks control The immobilizer is pro...

Страница 10: ...nation with remote and automatic start systems The small size and specific locking module design allow it to be installed under the hood in the standard wire bundle Anti detection protection of lockin...

Страница 11: ...ents Automatic control of door hood locks i95 LUX i95 Data link protection Original dialog authorization method The dialog between the system components utilizes a hardware random number generator and...

Страница 12: ...or locks when the owner carrying a label gets closer to further from the parked vehicle Universal channel connection method Determines the operation mode of the universal channel dedicated for utilizi...

Страница 13: ...tion module in the following cases Detection of a label upon turning on the ignition The label is lost while in the normal mode Locking expected notification Label battery low indication Light indicat...

Страница 14: ...6 i95 LUX i95 2 4 i95 ECO Current consumption when ignition is ON mA 6 8 0 2 Permissible switching current via relay contacts A 10 Permissible switching current at lock control outputs A 20 Operating...

Страница 15: ...y threshold is individually set by user which allows to eliminate the possibility of false tripping when using remote and automatic engine start systems The locking module is the key component of the...

Страница 16: ...icle fit with an immobilizer you need to have it at hand The codes exchanged via a radio link between a label and the locking module during the trip prevent locking of the engine All attempts to drive...

Страница 17: ...passenger compartment Each label uses a single battery of either the CR2025 or CR2032 type The average lifetime of a battery is 12 months The actual lifetime depends on the manufacture quality of the...

Страница 18: ...flashes of the built in LED will appear To commission a label press its button several times so that the flashes color changes to green Audible alarm unit i95 i95 ECO The audible alarm unit is instal...

Страница 19: ...in the locking module Indicates the label battery charge Allows entering the unlock code Allows entering the programing mode or the device registration mode The system allows registration of only one...

Страница 20: ...cking module Audible alarm unit Indication module Label Installed in a concealed location within the passenger or engine compartment Performs locking of the engine in case of theft or hijacking A spec...

Страница 21: ...sn t move then the locking is not performed This allows using the immobilizer together with other systems of automatic and remote engine start Locking algorithm If by the moment the vehicle begins mov...

Страница 22: ...ntermittently opening and closing back the locked circuit according to the following algorithm Locking stages LOCK Pause LOCK Pause LOCK Pause LOCK Duration sec 2 2 3 2 5 2 20 Riding the vehicle will...

Страница 23: ...tting up the immobilizer service mode telematic setup mode parameter programing mode turning off protection functions when either the battery discharges or a label is lost emergency unlock mode and re...

Страница 24: ...label Turning on locking Possible Parameter Additional modes Service Telematic setup Emergency unlock Parameter programing Device registration Indicator color label indication module Setting mode Usin...

Страница 25: ...ul data exchange a label has to be located inside the passenger compartment From then on the presence or absence of the label does not affect the immobilizer operation engine locking will not be engag...

Страница 26: ...ollowing additional modes Th e service mode is used for temporary turning off the protection i e during maintenance The engine is not locked in this mode irrespectively to presence or absence of label...

Страница 27: ...use this mode in case the battery discharges or the label is lost The telematic setup mode is used for a quick and easy setup of the immobilizer using a PC The parameter programing mode is used for ch...

Страница 28: ...reshold of the parked vehicle The ignition is turned off while the Open if ignition off option is on Switching over to the emergency unlock mode after entering the unlock code Switching to the service...

Страница 29: ...is present The ignition is turned off while the Open if ignition off option is on Switching over to the emergency unlock mode after entering the unlock code Switching to the service mode The Close pu...

Страница 30: ...lgorithms Hood lock control by ignition status The Open hood pulse is sent when Turning off the ignition while a label is present Switching over to the emergency unlock mode after entering the unlock...

Страница 31: ...ed vehicle Switching over to the emergency unlock mode after entering the unlock code Switching to the service mode The Close hood pulse is sent when A label is carried behind the away threshold of th...

Страница 32: ...ve the label in the passenger compartment at the moment of turning on the ignition while its further presence or absence will have no effect on the engine operation Engine locking expected alert All a...

Страница 33: ...battery is low three short consecutive audible signals are produced when the ignition is turned on The low status of the label battery is also indicated by three red flashes shown upon pressing the la...

Страница 34: ...bilizer s operation mode 3 T h e second flash indicates the presence of a stable connection between the label and the locking module If you see no second flash there is a connection problem between th...

Страница 35: ...nd indication period of the next protection mode 3 If the mode change has been done successfully it would be confirmed by a LED flash and its color would correspond to the new operation mode An exampl...

Страница 36: ...nce normal anti theft normal and so on The transition between different protection modes may even be performed outside the car The selected operation mode will be set after the first successful code e...

Страница 37: ...e area 1 Press and hold down the label button Upon being pressed the label will immediately indicate the current operation mode and the status of communication with the locking module Then a 2 second...

Страница 38: ...tered within the immobilizer are lost quitting the service mode becomes impossible CAUTION Full discharge of the battery de energizes the label This in turn locks the engine When you notice a battery...

Страница 39: ...e and can be changed by the end user If the unlock code is entered incorrectly you will hear a long signal If within the last 30 minutes the code was consequently entered wrong 5 times the code enter...

Страница 40: ...n module button You have successfully entered the first digit 3 Enter the rest of the digits of the unlock code according to 2 4 If the service code is entered correctly you will hear 3 short signals...

Страница 41: ...code has been entered incorrectly three short audible signals are produced and the system switches over to the emergency unlock code mode 5 Turn the ignition on If the service code is entered correct...

Страница 42: ...ck mode see page 40 Leave the ignition on Then perform the following actions 1 Quickly press the indication module button The LED will begin flashing in yellow 2 Within the next 2 minutes press the in...

Страница 43: ...ample Entering the 1798 unlock code Switching to the programing mode The immobilizer will stay in the programing mode while the ignition remains on 43 Pressing module button 3 sec Light signal up to 2...

Страница 44: ...1 After 20 seconds you will hear a long 10 sec signal While the signal is on turn off the ignition 2 Turn on the ignition You will hear 5 quick audible confirmation signals The system will switch to t...

Страница 45: ...the programing mode The immobilizer will stay in the programing mode while the ignition remains on 45 On On Off Off On Off On Off Off On Ignition Audible signal after 20 sec 10 sec Once 7 times 9 time...

Страница 46: ...second green flashes 2 Quickly press the label button when the LED is lit Before the LED blinks off you will see a short green flash The LED will change its color to red 3 While the LED is red press...

Страница 47: ...series will equal to the first digit the second series to the second digit and so on Switching to the unlock code change mode Example Entering the new 5678 unlock code 47 Pressing label button Light...

Страница 48: ...ed CAUTION The cipher codes exchange during the registration is executed via a radio link in a plain form We recommend performing the registration procedure while the vehicle is located outdoors and a...

Страница 49: ...ilizer will stay in the device registration mode while the ignition remains on 49 Pressing module button 3 sec Light signal up to 2 minutes Audible signal Once Once 7 times 9 times 8 times 3 times 7 t...

Страница 50: ...rform the following actions 1 After 20 seconds you will hear a long 10 sec signal While the signal is on turn off the ignition 2 Turn on the ignition You will hear 7 quick audible confirmation signals...

Страница 51: ...code Switching to the device registration mode 51 On On Off Off On Off On Off Off On Ignition Audible signal after 20 sec 10 sec Once 7 times 9 times 8 times On Off On Ignition Audible signal after 20...

Страница 52: ...nished the LED will flash in red 3 To switch the label to the normal operation mode remove and place back the battery 4 Repeat 1 and 3 for all other labels being registered 5 Turn off the ignition to...

Страница 53: ...hold the indication module button for at least 3 seconds then release it 4 If the indication module has been registered successfully you will see the LED flash in green In case of a registration error...

Страница 54: ...the LED color will indicate the operation mode see page 23 If for some reason i e due to high noise present the connection with the locking module can t be established the indication module will issue...

Страница 55: ...will turn off for a while Then it will start blinking in green and the number of flashes will equal to the number of the registered labels 3 2 seconds after the green flash series you will red flashes...

Страница 56: ...rves the right to modify its designs or elements without notice Manufactured by Scientific production association StarLine Limited Liability Company OOO NPO StarLine 9 Komissara Smirnova St Saint Pete...

Отзывы: