Star PRNT Command Specifications
2-73
<Function 367> ESC GS ( k pL pH cn fn n (cn=51, fn=67)
[Name] 2D GS1 DataBar: Set module siz
[Code] ASCII
ESC GS
(
k pL pH cn fn
n
Hex.
1B 1D 28 6B pL pH cn fn
n
Decimal
27 29 40 107 pL pH cn fn
n
[Defined Area]
pL = 3, pH = 0
cn = 51
fn = 67
2
≤
n
≤
8
[Initial Value]
n = 2
[Function]
Sets 2D GS1 DataBar module width to n dots.
[Details]
The setting of this function affects processes of Functions 081 and 082.
This setting is valid until ESC @ is executed, the printer is reset or the power is turned off.
Set in units of 1 dot.
The width is set in 0.125 mm (1/203 inches) units.
[Reference]
ESC GS ( k Function 381, ESC @
<Function 371> ESC GS ( k pL pH cn fn nL nH (cn=51, fn=71)
[Name] 2D GS1 DataBar: Set The maximum width of the 2D GS1DataBar Expanded Stacked
[Code] ASCII
ESC GS
(
k pL pH cn fn nL nH
Hex.
1B 1D 28 6B pL pH cn fn nL nH
Decimal
27 29 40 107 pL pH cn fn nL nH
[Defined Area]
pL = 4, pH = 0
cn = 51
fn = 71
106
≤
n
≤
3952
[Initial Value]
(nL + nH x 256) = 141 (nL = 141, nH = 0)
[Function]
The maximum width of the 2D GS1DataBar Expanded Stacked is set to n dots.
[Details]
The setting for this function affects the processing of function 381.
This setting is enabled until ESC@ is executed, the printer is reset, or the power is turned off.
The set unit is 1 dot.
The width is set as 0.125 mm (1/203 inches).
[Reference]
ESC GS ( k Function 381 , ESC @