SM SYGNUS SHC USER´S MANUAL
14
Link configuration
• MU ID: Configure the MU ID to be identical to the MU’s MAC address.
• Channel: select the desired channel to operate on.
• SU MAC Address: Configure the SU MAC address.
• DL Rate: Select the modulation for the downlink traffic (from the MU to the SU).
• UL Rate: Select the modulation for the uplink traffic (from the SU to the MU).
• Channel BW: Select the required channel bandwidth – 40/20/10/5 MHz The same
value should be configured in both MU and SU. Default – 20 MHz
• Enable MIMO: For Sygnus SHC only – activate/deactivate 2x2 MIMO. The same
value should be configured in both MU and SU. Default – enabled in Sygnus SHC.
• Current Rate: Shows the current modulation for DL and UL.
• Pre-Shared Key: Configure the AES pre-shared key (used when AES is enabled). The
same shared key should be configured in both MU and SU.
• Enable AES: Check to enable AES encryption. Default – disabled.
• Enable AIS: Check to enable Automatic Interference Sensibility. Default – enabled.
• Enable ACS: Check to enable Automatic Channel selection after AU power cycle.
• Default – enabled.
• Perform ACS: Press this button to start Automatic Channel selection immediately.
• VLAN ID: management VLAN ID (default – 0, no VLAN ID).
• Sync Unit: After configuring all parameters, press “Sync Unit” to submit the
configuration to the MU.