Standard Pump SP-430EX Скачать руководство пользователя страница 1

Operation & Parts Manual 

Models

: SP-430EX & SP-440EX

OIPM

-EXP-

0

8

18

Содержание SP-430EX

Страница 1: ...Operation Parts Manual Models SP 430EX SP 440EX OIPM EXP 0818...

Страница 2: ...ein is considered incorrect and consequently Standard Pump Inc shall not be held responsible for any damages to people or property In case of doubt or inquiries please apply to our Technical Service d...

Страница 3: ...se the motor in liquid ALWAYS use an ATEX Zone 1 approved plug and receptacle for ATEX motor models ALWAYS use a UL CSA Class I Division 1 Group D approved plug and receptacle for Hazardous Location m...

Страница 4: ...le raccorder l alimentation lectrique NE JAMAIS immerger le moteur dans un liquide TOUJOURS utiliser une prise et une prise homologu es ATEX Zone 1 pour les mod les de moteurs ATEX TOUJOURS utiliser u...

Страница 5: ...th pump tube prior to operation Note Do not use hand tools to tighten the nut as this may cause damage to the motor casing Figure 1 Grounding of ATEX Haz Loc Motors Models SP 430EX SP 440EX When opera...

Страница 6: ...amp up to the previously set speed When the unit s power is disconnected the stored speed is set back to the default speed Keypad Figure 2 The Red LED indicates a motor fault When the motor faults it...

Страница 7: ...uty Cycle Enclosure IP55 TEFC 3 0000 12 000 RPM None Continuous Duty 230V 50 60 Hz SP 440EX 115V 60 Hz Haz Loc CLASS I DIVISION 1 GROUP D T4 None TEFC SP 430EX Certifications Approvals 3 0000 12 000 R...

Страница 8: ...EU Directive on machinery safety provided pumps manufactured by Standard Pump Inc are used This declaration is valid provided that the devices are fully assembled and no modifications are made to the...

Страница 9: ...s for Driving Drum and Container Pumps Pump Motor Models SP 440EX EU Directives Equipment and protective systems intended for use in potentially explosive atmospheres 2014 34 EU EU Type Examination Ph...

Страница 10: ...shall cover the replacement or repair of any part s which is documented to be faulty due to construction or assembling with a new or repaired part s free of charges delivered by Standard Pump Inc Part...