DS41
Digital Depth Sounder
Owner’s Manual
Standard 2 Inch Installation
Dual Station Operation
NMEA Repeater
Reads in Feet Fathoms or Meters
Adjustable Prop or Surface Offset
Shallow and Deep alarms
Dual
Station
Operation
Страница 1: ...tal Depth Sounder Owner sManual Standard 2 Inch Installation Dual Station Operation NMEA Repeater Reads in Feet Fathoms or Meters Adjustable Prop or Surface Offset Shallow and Deep alarms Dual Station Operation ...
Страница 2: ...sure 5 Troubleshooting 6 What comes with your Digital Depth Sounder 7 Standard 7 Options 7 Replacement Parts 8 Installation 9 Face Plate Installation 9 Instrument Installation 9 Transducer Installation 11 General 11 Sailboats 12 Powerboats 12 Transom Installation 13 In Hull Installation 13 Appendix A Dual Station Operation 14 Master Slave Selection 14 Linked or Separate Selection 15 Appendix B NME...
Страница 3: ... 5 VDC to 16 5 VDC Operating Temperature 0 C to 50 C 32 F to 122 F Current Drain 150mA max including internal buzzer Data Input Output Single wire data output Input Dual station mode outputs NMEA DPT sentence Dual station inputs NMEA DPT sentence In the linked mode a dual station pair also transfer function settings eg Alarm on off NMEA Output DPT NMEA Input DPT and DBT External Buzzer Output 12VD...
Страница 4: ...e lower right corner of the display will show next to the Alarm Bell to indicate that the alarms are on 120 OFF ON ON V To turn the alarms off press the OFF key The arrow in the lower right corner will extinguish 120 OFF OFF ON V V Note The arrow will flash if alarms are turned ON but the shallow alarm is individually set to OFF See next section Shallow Alarm To set the shallow alarm 1 Press the k...
Страница 5: ...e disabled by pressing both the and keys for 5 seconds The word will be displayed but the alarm depth will be retained for future use Press for 3 Seconds Instrument Setup Keel Surface Offset An offset may be automatically added to or subtracted from the depth reading to compensate for the location of the transducer This allows the instrument to indicate the water depth relative to the bottom of th...
Страница 6: ...ottom The setting is used to increase the required level that shallow echoes must meet before they will be displayed If the D41 gives repeated false readings of 1 5 to 3 feet depth while in deep water the transducer setting should be increased Adjust it upward by 0 5 at a time and retest The range of values is 0 9 to 2 5 If the value is set too high it could cause erratic readings in shallow water...
Страница 7: ... of corrosion Erratic readings while moored Check transducer for growth or multiple coats of paint Erratic readings while moving Cavitation air under the face of the transducer Review installation and reinstall if necessary Erratic readings only while engine is running 1 Re route power and transducer cables away from engine ignition wires and battery cables 2 Add feed through filter capacitor on t...
Страница 8: ...r Standard Mounting Bracket With mounting hardware Extension Power Cord 6 feet long with quick disconnect connectors Twist Lock Face Plate Round Options DTS50 Plastic Low Profile Transducer DTS51 Transom Mount Transducer DTS52 Bronze Long Stem Thru hull Transducer ...
Страница 9: ...e ordered from the Parts Department To order call Toll free Number 1 800 487 2788 Square Face Plate Part Number 568001012A Round Face Plate Part Number 568002012A Gasket Part Number RRDS410001 Mounting Bracket Part Number 160001020A Mounting Nut Part Number 580010123A DTS53 Bronze Low Profile Transducer DTS55 In Hull Transducer ...
Страница 10: ...directly as possible minimising the length of cable where practical Location should provide as much protection from the elements as possible The panel for mounting the instrument should be 1 8 to 3 4 inch thick The space behind the instrument panel must have a depth of at least 3 75 inches See Figure 1 for dimensions of the instrument 2 Drill a 2 inch hole on the instrument panel in the selected l...
Страница 11: ...der Installation FACE PLATE INSTRUMENT PANEL WALL MOUNTING BRACKET MOUNTING NUT DEPTH SOUNDER BODY 7 Obtain the power from a 12 V source as directly as possible Avoid power circuits which share loads with ignition alternators radio transmitters etc Excessive electrical noise associated with such devices may prevent the instrument from operating properly 8 Connect the RCA phono plug on the transduc...
Страница 12: ...as taken place Erosion is caused by turbulent water and these areas are unsuitable transducer mounting locations It is very important that the mounting location have reasonable access from inside the vessel since the transducer will require tightening from inside the hull Plastic thru hull transducers should be mounted in fiberglass and metal hulls only Under no circumstances should they be used i...
Страница 13: ...h as trawlers the transducer should be mounted amidships relatively close to the keel centerline of the hull On planing powerboat hulls the transducer should be mounted well aft and close to the keel to ensure that the transducer is in contact with water at higher boat speeds If the vessel is capable of speeds greater than 25 knots you may wish to review installation location and operational resul...
Страница 14: ...side the hull construct a water box to be used for installation 4 Use a PVC pipe with one end threaded and supplied with a screw on cap The PVC pipe should be 1 4 inch bigger than the bottom face of the transducer 5 Install the transducer as shown in Figure 7 6 To receive a proper echo from the bottom the bottom of the PVC pipe may have to be cut at the deadrise angle of the hull Transom Installat...
Страница 15: ...depth received from the master but have independent alarm settings and keel offset values Note The instrument designated as the master device is the only instrument connected to the depth transducer See the Wiring Connection section for dual station wiring details Also see the Instrument Setup section for configuration details Master Slave Selection To select the master slave mode of operation 1 A...
Страница 16: ...tation pair of DS41 instruments automatically keep the following settings the same in both instruments Alarms On Off Alarm Values Deep and Shallow Keel Offset see note Units of measure see note Example Switching an alarm off on the slave instrument will also switch the alarm off on the master instrument The reverse also applies alarms changed on the master will be automatically changed in the slav...
Страница 17: ... between and SL This will occur if the master unit has no depth reading or if the data link from the master is inadvertently broken Brown NMEA data input A B Orange Black Red 1A Fuse 12 VDC Ground Optional External D C Buzzer ON OFF Switch NMEA Output _ 12V 100 mA maximum Note Transducer not connected Ground Horizon Depth OFF ON DS41 Operating as NMEA repeater Depth Sounder with NMEA DPT output To...