Service Manoskop

®

730N

Technical description

The Manoskop

®

730N is an adjustable 

torque wrench with cut-out function, 
audible and tactile cut-out signals.

The torque wrench has a safety cut-
out mechanism.

The cut-out level can be very quickly 
and precisely set with little physical 
effort by means of a setting knob. 

The required value is secured by 
means of a fail-safe mechanism on 
the control knob.

The measuring element is a flexible 
rod. The rod is not pre-tensioned and 
therefore only under tension from 
start to finish of the actual tightening 
operation. After use it is not 
necessary to reset to the lowest 
value.

As soon as the torque wrench is 
released, it is ready for the next job.

The ergonomically-shaped two-
component handle allows for 
comfortable and safe operation. The 
correct grip is indicated optically and 
tactually.

List of contents

Technical description .................  25

ã

Important safety points ..........  28

Operation ...................................  29
Maintenance...............................  40
Cleaning the Manoskop

®

...........  46

Accessories................................  46
Disposal .....................................  47

Содержание Manoskop 730N

Страница 1: ...he control knob The measuring element is a flexible rod The rod is not pre tensioned and therefore only under tension from start to finish of the actual tightening operation After use it is not necess...

Страница 2: ...urrently set loosening value is 3 The Manoskop 730N complies with DIN EN ISO 6789 Type II Class A Every Manoskop has a unique serial number and is supplied with a works calibration certificate Service...

Страница 3: ...0 450 1 50 2 5 in lb 9 x 12 330 825 20 100 15 75 10 2 5 0 5 N m 9 x 12 386 980 0 15 75 180 900 2 5 100 5 in lb 9 x 12 386 980 25 130 20 95 10 2 5 0 5 N m 14 x 18 421 1120 40 200 30 150 10 5 1 N m 14 x...

Страница 4: ...the information contained in this instruction booklet in particular the safety instructions and technical tolerance limits The buyer is required to ensure that all users comply with these instructions...

Страница 5: ...f an inspection shows that there is excessive deviation the torque wrench will have to be readjusted see page 43 Additional important safety points may apply depending on the application These are fou...

Страница 6: ...maged After such an overload the readings may be inaccurate in such a way that the user does not notice Selecting the inserts and insert tools CAUTION When using inserts on torque wrenches with a squa...

Страница 7: ...ert tools made by STAHLWILLE DANGER Check the extension adjustment size for the insert tool being used If the extension adjustment size deviates from the standard adjustment then a correction of the s...

Страница 8: ...the screw or bolt CAUTION Use of home made special tools may be dangerous If you need to manufacture your own tools please contact STAHLWILLE first DANGER When using insert tools ensure that the lock...

Страница 9: ...n of the QuickRelease safety lock of the insert tool is depressed by the insertion groove Slide the insert tool further until it stops Ensure that the locking pin engages in the locating hole 3 Check...

Страница 10: ...f the tool was attached in the normal position press the QuickRelease button on the underside of the wrench head A 2 If the tool was attached to the torque wrench rotated through 180 insert a fine pun...

Страница 11: ...the main scale Torque levels indicated in the measurement area shown in green are only ever set on the main scale Setting torque levels using the black graduations The cut off levels are set by turnin...

Страница 12: ...or a desired setting of 62 5 N m set the level to 2 5 N m 5 Check the correct setting again 6 When you have set the desired value press the control knob back into the locking position The knob engages...

Страница 13: ...which lies under the desired setting 4 Set the desired value Example Manoskop 730N 10 52 5 ft lb At this setting you can disregard the values on the fine scale 5 Check the correct setting again 6 Whe...

Страница 14: ...has to be rotated through 180 Ratchet insert tools also need switching to L CCW for the correct tightening direction Uncontrolled loosening of nuts bolts opposite to the tightening direction is possib...

Страница 15: ...without any interruption particularly during the final phase until you feel a jerk and hear a click The torque level set on the scale has now been reached DANGER Before you use the wrench check that...

Страница 16: ...equipment inspection to ISO 9000 et seq an inspection must take place after approx 5000 operations or every 12 months whichever is the shorter The time frame 12 months starts with the first usage If i...

Страница 17: ...ou Here we demonstrate the inspection using the Manoskop 730N 10 To carry out the test proceed as follows 1 Set the torque wrench to the highest scale reading 2 Operate the torque wrench five times en...

Страница 18: ...e that the readings shown on the torque tester are not more than 3 09 greater and not more than 2 91 smaller than the value set on the torque wrench 7 Set the torque wrench to the highest scale readin...

Страница 19: ...self In this case however STAHLWILLE s accuracy guarantee is void A torque tester of sufficient capacity and accuracy is required for making readjustments Every Manoskop has two adjusting screws insid...

Страница 20: ...he mechanisms from dirt these two holes are plugged To adjust the wrench you will need the torque tester and an Allen key size 2 mm Proceed as follows 1 Remove both plugs using a sharp implement Retai...

Страница 21: ...torque tester 5 Repeat the adjustment of one or both screws and the testing process until the deviation has been compensated 6 Finally do a thorough test again Proceed as described under Checking the...

Страница 22: ...engine oil for this Remove any oil remaining with a clean cloth Accessories Inserts for square drives for all usual screw head types and sizes Insert tools ratchet insert tools square insert tools op...

Страница 23: ...esting and readjusting incl accuracy guarantee and new works calibration certificate Disposal When the tool finally has to be disposed of please observe your local environmental protection laws The ha...

Страница 24: ......

Страница 25: ...03 42331 Wuppertal Lindenallee 27 42349 Wuppertal Germany Tel 49 2 02 47 91 0 Fax 49 2 02 47 91 2 00 E Mail info stahlwille de Internet www stahlwille de KONTECXT GmbH Technische Dokumentation 45239 E...