Specifications for mains connection
•
All poles of the mains cable must be disconnected by a lockable switch.
•
The mains voltage must correspond to that stated on the rating plate.
•
Fixed installed cables e.g. NYM, NYY
•
Flexible cables e.g. RN-F, NGFLGöu, H07VVH2-F
•
Cable cross-section min. 1.5 mm2
•
Mains voltage 380-415 VAC, 50 Hz
•
Other mains voltages are available as options.
•
In accordance with EN 50014 a radio interference suppression module FEM1 must be
installed for all motors
1 kW
•
If a current-operated circuit-breaker is used, a fault current of approx. 17 mA must be
taken into account for each FEM1.
9.4.1
Max. length of supply cable 50 Hz
Direct control
50 Hz
Max. cable length with direct control [m]
Chain hoist
Stationary *1
With trolley along runway *2
Cable cross-section
1.5 mm²
2.5 mm²
1.5 mm²
2.5 mm²
230 V
400 V
500 V
230 V
400 V
500 V
230 V
400 V
500 V
230 V
400 V
500 V
H
oi
st
m
ot
or
ty
pe
*
2A04
2/8A04
57
170
269
94
283
-
29
80
120
49
-
-
2E21
8/2E21
17
18
50
55
79
87
28
31
84
92
131
144
10
11
30
33
47
52
17
18
50
55
79
87
2E22
8/2E22
13
14
38
42
60
65
21
23
64
70
99
109
8
8
23
25
36
39
13
14
38
42
60
65
2E31
8/2E31
11
11
34
34
53
53
19
19
57
57
89
89
7
7
21
21
32
32
11
11
34
34
53
53
Contactor control
50 Hz
Max. cable length with contactor control [m]
Chain hoist
Stationary *3
Stationary *3
Cable cross-section
1.5 mm²
2.5 mm²
1.5 mm²
2.5 mm²
230 V
400 V
500 V
230 V
400 V
500 V
230 V
400 V
500 V
230 V
400 V
500 V
H
oi
st
m
ot
or
ty
pe
*
2A04
8/2A04
113
340
531
-
-
-
71
214
334
118
-
-
2E21
8/2E21
36
40
109
122
170
190
60
67
181
203
283
317
27
29
81
89
126
139
44
49
134
148
210
231
2E22
8/2E22
27
30
81
90
112
141
45
50
135
150
121
234
20
22
61
67
96
104
34
37
102
111
159
174
2E31
8/2E31
24
24
73
73
113
114
40
40
121
122
189
190
18
18
55
55
86
86
30
30
91
91
143
142
2E32
8/2E32
-
15
45
45
60
70
21
25
75
75
99
117
-
11
34
34
46
54
16
19
57
57
77
90
8/2E42
-
36
56
20
60
93
-
28
43
15
46
72
* Allocation to chain hoists see "Motor data" table
*1 Voltage drop 2.5%
*2 Voltage drop 1.5%
*3 Voltage drop 5.0%
*4 Voltage drop 4.0%