Faults
Fault 347: Trouble Reinstalling Sparge Tube
Causes
Troubleshooting
Fixes
• Scale buildup on tip of sparge
tube.
• Grind/Polish the last 6 inches of the sparge tube to fit into the
support sleeve.
Fault 348: Touch Screen Rebooting When Generator Starting
Causes
Troubleshooting
Fixes
• Low battery.
• Charge/Replace battery.
• Loose connection on 12 V inline
fuse.
• Inspect/Tighten connection.
• Loose ground connection.
• Check battery ground to engine
frame.
• Tighten ground.
• Faulty 24 V regulator.
• Replace 24 V regulator.
Fault 349: Boiler Taking Longer Than Normal to Heat Up
Causes
Troubleshooting
Fixes
A new properly tuned 6210 will take 12 minutes to heat from 100° F to 180° F.
• Sooted up flue tubes.
• See test 15 to clean the flue
tubes. Fault 208 will normally
appear with dirty flue tubes
during high fire.
• Clean flue tubes.
• Faulty/Clogged low fire nozzle.
• Remove, inspect, and clean the
low fire nozzle. See nozzle page.
• Clean/Replace low fire nozzle.
• Restriction in fuel path.
• Inspect fuel path. 2015
machines won’t display nozzle
pressure faults.
• Remove restriction(s) in fuel
path.
• Severe scale on water side of
boiler tubes.
• Inspect boiler tubes.
• Use REDEW boiler de-scaler
(Part # 11194).
• Use Boiler Guard
(preventative).
Fault 397: Purge Delay: T19 High Fire Jumpered (See Fault 221)
Indicates that the burner louver actuator is in the open position before the 30 second purge starts (Can
cause an extra long purge).