Comparator (COMP)
686
22.3.3
COMP reset and clocks
The COMP clock provided by the clock controller is synchronous with the APB2 clock.
There is no clock enable control bit provided in the RCC controller. Reset and clock enable
bits are common for COMP and SYSCFG.
Note:
Important:
The polarity selection logic and the output redirection to the port works
independently from the APB2 clock. This allows the comparator to work even in Stop mode.
22.3.4 Comparator
LOCK
mechanism
The comparators can be used for safety purposes, such as over-current or thermal
protection. For applications having specific functional safety requirements, it is necessary to
insure that the comparator programming cannot be altered in case of spurious register
access or program counter corruption.
¾ V
REFINT
010
V
REFINT
011
DAC Channel1
100
DAC Channel2
101
PB1
110
PC4
111
Table 142. COMP2 input plus assignment
COMP2_INP
COMP2_INPSEL
PB4
0
PB6
1
Table 143. COMP2 input minus assignment
COMP2_INM
COMP2_INMSEL[2:0]
¼ V
REFINT
000
½ V
REFINT
001
¾ V
REFINT
010
V
REFINT
011
DAC Channel1
100
DAC Channel2
101
PB3
110
PB7
111
Table 141. COMP1 input minus assignment (continued)
COMP1_INM