Reset and clock control (RCC)
RM0351
234/1830
DocID024597 Rev 5
6.4.8
Clock interrupt flag register (RCC_CIFR)
Address offset: 0x1C
Reset value: 0x0000 0000
Access: no wait state, word, half-word and byte access
Bit 2
MSIRDYIE
: MSI ready interrupt enable
Set and cleared by software to enable/disable interrupt caused by the MSI oscillator
stabilization.
0: MSI ready interrupt disabled
1: MSI ready interrupt enabled
Bit 1
LSERDYIE
: LSE ready interrupt enable
Set and cleared by software to enable/disable interrupt caused by the LSE oscillator
stabilization.
0: LSE ready interrupt disabled
1: LSE ready interrupt enabled
Bit 0
LSIRDYIE
: LSI ready interrupt enable
Set and cleared by software to enable/disable interrupt caused by the LSI oscillator
stabilization.
0: LSI ready interrupt disabled
1: LSI ready interrupt enabled
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Res.
Res.
Res.
Res.
Res.
HSI48
RDYF
LSE
CSSF
CSSF
PLLSAI
2RDYF
PLLSAI
1RDYF
PLL
RDYF
HSE
RDYF
HSI
RDYF
MSI
RDYF
LSE
RDYF
LSI
RDYF
r
r
r
r
r
r
r
r
r
r
Bits 31:11 Reserved, must be kept at reset value.
Bit 10
HSI48RDYF
: HSI48 ready interrupt flag (only on STM32L496xx/4A6xx devices)
Set by hardware when the HSI48 clock becomes stable and HSI48RDYIE is set in a
response to setting the HSI48ON (refer to
Clock recovery RC register (RCC_CRRCR)
Cleared by software setting the HSI48RDYC bit.
0: No clock ready interrupt caused by the HSI48 oscillator
1: Clock ready interrupt caused by the HSI48 oscillator
Bit 9
LSECSSF
: LSE Clock security system interrupt flag
Set by hardware when a failure is detected in the LSE oscillator.
Cleared by software setting the LSECSSC bit.
0: No clock security interrupt caused by LSE clock failure
1: Clock security interrupt caused by LSE clock failure
Bit 8
CSSF
: Clock security system interrupt flag
Set by hardware when a failure is detected in the HSE oscillator.
Cleared by software setting the CSSC bit.
0: No clock security interrupt caused by HSE clock failure
1: Clock security interrupt caused by HSE clock failure