Power control (PWR)
RM0351
188/1830
DocID024597 Rev 5
5.4.9
Power Port A pull-down control register (PWR_PDCRA)
Address offset: 0x24.
Reset value: 0x0000 0000. This register is not reset when exiting Standby modes and with
PWRRST bit in the RCC_APB1RSTR1 register.
Access: Additional APB cycles are needed to access this register vs. a standard APB
access (3 for a write and 2 for a read).
5.4.10
Power Port B pull-up control register (PWR_PUCRB)
Address offset: 0x28.
Reset value: 0x0000 0000. This register is not reset when exiting Standby modes and with
PWRRST bit in the RCC_APB1RSTR1 register.
Access: Additional APB cycles are needed to access this register vs. a standard APB
access (3 for a write and 2 for a read).
Bits 31:16 Reserved, must be kept at reset value.
Bit 15
PU15
: Port A pull-up bit 15
When set, this bit activates the pull-up on PA[15] when APC bit is set in PWR_CR3 register.
The pull-up is not activated if the corresponding PD15 bit is also set.
Bit 14 Reserved, must be kept at reset value.
Bits 13:0
PUy
: Port A pull-up bit y (y=0..13)
When set, this bit activates the pull-up on PA[y] when APC bit is set in PWR_CR3 register.
The pull-up is not activated if the corresponding PDy bit is also set.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Res.
PD14
Res.
PD12
PD11
PD10
PD9
PD8
PD7
PD6
PD5
PD4
PD3
PD2
PD1
PD0
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Bits 31:15 Reserved, must be kept at reset value.
Bit 14
PD14
: Port A pull-down bit 14
When set, this bit activates the pull-down on PA[14] when APC bit is set in PWR_CR3
register.
Bit 13 Reserved, must be kept at reset value.
Bits 12:0
PDy
: Port A pull-down bit y (y=0..12)
When set, this bit activates the pull-down on PA[y] when APC bit is set in PWR_CR3 register.