Motor control operations
UM0432
30/53
Start-up stator frequency
Sets the stator frequency during the start-up sequence (only in closed loop).
Max duration
Sets the maximum duration of the start-up sequence in milliseconds (ms) (only in
closed loop).
Min rotor frequency to validate
closed loop
Sets the rotor speed or frequency to validate the closed-loop mode (only in closed
loop).
Regulator settings
Integral coefficient (Ki)
Sets the value of the integral coefficient (Ki) of the proportional integrative (PI)
regulator.
Proportional coefficient (Kp)
Sets the value of the proportional coefficient (Kp) of the PI regulator.
Sampling time
Sets the regulator sampling frequency in milliseconds (ms).
Phase shift
Set phase shift according to
Ph/F Curve
Software sets (in run time) the actual phase shift from the Ph/F curve defined in
the advanced settings (based on the rotor speed).
Set phase shift according by
P3
Manual setting of the phase shift using potentiometer P3; the maximum CCW
position is 0° of phase shift and the maximum CW position is 360° of phase shift.
Change motor type
The
Change Motor Type
button enables the user to change the motor type (see
Figure 13
).
Advanced settings
The
Advanced Settings
button enables the user to set the advanced parameters
(see
Section 7.4.7
).
Generate source files
The
Generate Source Files
button enables the user to generate the configuration
".h" files shown in
Table 7: ".h" configuration files
. A "Save" dialog window appears,
where the user can select the folder in which to create the file. The user must
choose the correct "source" directory in the firmware working folder (see
Section 7.4.1
).
Table 10.
"3-phase PMAC motor (sinewave)" basic parameters (continued)
Parameter name
Description