4.
FSM_Start
: is related to the burst mode operation of the power converter. During this procedure, the PWM
is activated. The pulse sequence at a fixed duty cycle allows boosting the input voltage and increasing the
DC output voltage at a reference voltage. The state machine then moves to
FSM_Run
state.
Figure 43.
FSM_Start block diagram
5.
FSM_Run
: if the startup procedure is completed without any issue,
FSM_Start
manages the PFC operation
of the power converter. The burst operation still maintains the DC voltage. If a DC load occurs, the PFC
modulation and the control loop are activated to handle the load power demand.
Figure 44.
FSM_Run block diagram
2.6.2
Direct startup procedure
The finite state machine manages a direct startup procedure. The AC source takes the nominal voltage into
consideration. The inrush current limitation and the burst mode operation must be completed after the DC load
connection.