4.6
Q-factor accuracy test
The Q-factor measurement accuracy of the
dual-coil reference design should be close to
the LCR meter. The table below shows the test results.
Table 7.
Q-factor accuracy test with RMB coins
DTU
One Yuan
50 cents
10 cents
LCR
11.7
18.1
29.4
Coil 1
11.3
18.4
31.5
Coil 2
11.4
18.3
31.1
TN1399
Q-factor accuracy test
TN1399
-
Rev 1
page 11/26