Figure 18.
TCU faults
RGM
Error out
Reset request
reset
DFT_1
FCCU
INTC
Interrupt request
Interrupt
Fault #78
DFT_2
DFT_3
DFT_4
Fault #79
Fault #80
Fault #81
3.17.1
Test circuitry group 1 activation (fault #78)
In case of unwanted activation of the test circuitry in the related diagnostic function test domain, the event is
detected and forwarded to the FCCU.
The user cannot inject this fault.
3.17.2
Test circuitry group 2 activation (fault #79)
In case of unwanted activation of the test circuitry in the related diagnostic function test domain, the event is
detected and forwarded to the FCCU.
The user cannot inject this fault.
3.17.3
Test circuitry group 3 activation (fault #80)
In case of unwanted activation of the test circuitry in the related diagnostic function test domain, the event is
detected and forwarded to the FCCU.
The user cannot inject this fault.
3.17.4
Test circuitry group 4 activation (fault #81)
In case of unwanted activation of the test circuitry in the related diagnostic function test domain, the event is
detected and forwarded to the FCCU.
The user cannot inject this fault.
3.18
PBRIDGE faults
The PBRIDGE connects the XBAR interface to the register interface of the peripherals embedded within the
device. The device incorporates two peripheral bridges: PBRIDGE_1 and PBRIDGE_2. For further details on the
PRIDGEs, refer to the SPC582Bx microcontroller reference manual
AN5752
PBRIDGE faults
AN5752
-
Rev 1