How to control the RF and I²C channels from your screen
UM0853
20/49
Doc ID 16609 Rev 1
Select mode
Selecting the Select mode sets bit 5 and clears bit 6 in the Request_flags of the RF request
(bit 5 = 1 and bit 6 = 0).
The request is executed only by the M24LR64-R device in the Select State (please refer to
the M24LR64-R datasheet for details).
To select a tag, refer to the
SELECT
paragraph below, and to the M24LR64-R datasheet
(Select paragraph).
Figure 32.
Selecting the Select mode
3.2.5
Managing the M24LR64-R states
The M24LR64-R can be in different states: Power-off, Ready, Quiet and Selected (refer to
the M24LR64-R datasheet for details).
The interface shown in
Figure 33
is used to send three types of RF request to place the
M24LR64-R in one out of three specific states: Selected, Quiet and Ready.
Figure 33.
Device state management interface
SELECT
The
SELECT
button is used to send a Select RF request with the UID of a specific tag
(
Section 3.2.1: Inventory command
) (refer to the M24LR64-R datasheet for details).
If no tag was selected after the Inventory request, the device sends “00 00 00 00 00 00 00
00” instead of the UID value.
STAY QUIET
The
STAY QUIET
button is used to send a Stay Quiet RF request (refer to the M24LR64-R
datasheet for details).
RESET TO READY
The
RESET TO READY
button is used to send a Reset to Ready RF request (refer to the
M24LR64-R datasheet for details).
3.2.6 Read
command
Figure 34.
Initiating a read operation
electronic components distributor