L6470
Programming manual
Doc ID 16737 Rev 2
47/64
The OC_SD bit sets if an overcurrent event causes or not the bridges to turn-off; the OCD
flag in status register is forced low anyway:
The POW_SR bits set the slew rate value of power bridge output:
The EN_VSCOMP bit sets if the motor supply voltage compensation is enabled or not.
The F_PWM_INT bits set the integer division factor of PWM frequency generation.
Table 24.
Overcurrent event
OC_SD
Overcurrent event
1
Bridges shut down
0
Bridges do not shut down
Table 25.
Programmable power bridge output slew-rate values
POW_SR
[1..0]
Output Slew-rate
(1)
[V/µs]
1.
See S
Rout_r
and S
Rout_f
parameters in the electrical characteristics
for details.
0
0
180
0
1
180
1
0
290
1
1
530
Table 26.
Motor supply voltage compensation enable
EN_VSCOMP
Motor supply voltage compensation
0
Disabled
1
Enabled
Table 27.
PWM frequency: integer division factor
F_PWM_INT
[2..0]
Integer division factor
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1
4
1
0
0
5
1
0
1
6
1
1
0
7
1
1
1