ST 500 "Piranha" Operation Manual: Software
51
8. SOFTWARE
8.1. PURPOSE
1. Preparation and loading into ST 500 of a priori information for analyzing the received signals
using the "SELECTIVE HF DETECTOR" channel in AUTOMATED and "WIRELESS
COMMUNICATION" modes:
adjustment of "THREAT" and "NON-THREAT" frequency bands,
customizing the parameters frequency bands used by digital communications devices,
customizing the parameters of frequency bands used by base stations of mobile
communications networks,
making/editing user lists.
2. Updating the firmware of the main unit processor.
8.2. FUNCTIONALITY
The user can do the following
1.
Adjust the factory settings, then download the data to the device and/or save them as a file
on the HDD.
2.
Download data from the ST 500 or from the HDD, make the necessary changes, then upload
the corrected data to the device and/or save it as a file on the HDD.
Files on the HDD are saved in the "xxx.dat" format, ("xxxx" is the file name assigned by the
user when saved).
Only one file can be downloaded to the device, an unlimited number of files can be saved to
the HDD.
8.3. PC REQUIREMENTS
Operation System: Windows 7, 8, 10 (64 bit)
Free HDD space: at least 100 Mb
8.4. INSTALLATION
The distribution kit is located in the Prog_ST500 folder on the flash card supplied.
Installation Order:
1. Copy the Prog_ST500 folder to the PC.
2. Install the ST 500 driver on the PC (run the CDM21228_Setup.exe file).
3. Run the ST500.exe file.
4. Using the USB cable (fig.1, 5) connect the ST 500 main unit to the PC.
5. Turn on the main unit.
On the PC screen (on the status bar (fig.48, 7) should appear the inscription: "Подключено по
USB" or "USB connected". The following message should appear on the screen of the ST 500:
"USB connected". After that, the software is considered to be successfully installed on the PC.