IMPORTANT SAFETY INFORMATION 

 
The following general safety precautions have to be observed during all phases of 
operation,  service,  and  the  repair  of  this  equipment.  Failure  to  comply  with  these 
precautions or with specific warnings in this manual violates safety standards of 
design, manufacture, and the intended use of this equipment. 
 

Do not operate in an explosive atmosphere! 

 
Do  not  operate  this  equipment  in  the  presence  of  flammable  gases  or  fumes. 
Operation  of  any  electrical  instrument  in  such  an  environment  constitutes 
a definite  safety  hazard.  Device  should  be  never  placed  near  or  over  a  heat 
register  or  other  source  of  heated  air  and  it  should  not  be  installed  or  operated 
without proper ventilation.  

 
Mains AC 85-265V connection 

 

AC  power  is  connected  to  the  splitter  via  Neutrik  PowerCon  blue  connector. 
Standard  supply  is  UNISCHUKO  lead  with  Neutrik  PowerCon.  Always  respect  the 
markup of L and N on connector for correct wiring of Line and Neutral.  
 

DMX connection 

 

DMX  connectors  are  located  on  both  sides  of  the  splitter  board.  These  are 
separated to two groups. First group is wired in ration 1:1 and marked as DMX input 
and DMX thru. This line is not optically isolated and when the device is last in line, 
it should be terminated by the termination resistor of 120ohm wired between pins 2 
and 3 of the DMX thru connector. 
 
The other group consists of 4-way optically isolated lines marked with letters A-D. 
Each line has a separate power supply, line driver and the indication of signals D+, 
D- on both signal lines. These LEDs are active when splitter is retransmitting DMX 
signal and there is no short circuit between data lines. 
 
In  case  of  short  circuit  between  data  pins  D+/D-  and  the  CMN  pin,  the  LED 
connected to the data line is off. 

 

 

Pin 1   

Ground / Common 

Pin 2   

Data -  

Pin 3   

Data + 

 
 
 

Содержание DST4WH-3

Страница 1: ...ation about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the power to the equipment is disconnected before opening the equipment or commencing any maintenance work DST4WH_en_manual_M312 Wireless 4 way DMX AC Power Splitter DST4WH 3 DST4WH 5 DST4WH C ...

Страница 2: ......

Страница 3: ...werCon blue connector Standard supply is UNISCHUKO lead with Neutrik PowerCon Always respect the markup of L and N on connector for correct wiring of Line and Neutral DMX connection DMX connectors are located on both sides of the splitter board These are separated to two groups First group is wired in ration 1 1 and marked as DMX input and DMX thru This line is not optically isolated and when the ...

Страница 4: ...LEDs marked as D and D go ON for the side marked as DMX input thru and this indicates that DST4WH is receiving the DMX signal Speed of light on these LEDs also indicates the refresh rate of DMX signal Fast blinking high refresh rate slow blinking slow refresh rate On the rear panel of DST4WH there are outputs A D which are retransmitting the input to the optically isolated outputs If any of data L...

Страница 5: ...ntil it lights in green color The W DMX function button will indicate the W DMX functionality as shown on the bottom of this page To log off from a linked transmitter hold the W DMX Button for more than 5 sec There is an automatic backup of the W DMX line by a cable connection When DST4W unit is linked to the transmitter and the signal quality is poor W DMX active LED goes off and splitter retrans...

Страница 6: ...smitter Hold button on the Transmitter to start the linkage of DST4W 3 W DMX is linked DMX is missing on the Transmitter The W DMX LED signalizes this by blinking in red green color Bargraph is in an active state To disconnect from the Transmitter hold the W DMX button for 10 sec Module will turn to state 2 4 W DMX is linked to the Transmitter and is receiving the DMX signal Both indicators are in...

Страница 7: ...o 1000V Maximum of 4x 32 devices per one splitter output Cable length max 4x 1200m Housing Dimensions Lightweight aluminium box with powder coating 234x154x62mm Mounting points Located symmetrically on base plate 8mm wide hole for securing line Grid of mounting points 222x78mm 4x rubber foot on the bottom Weight 1 7 kg Temperature of use 10 ºC 45 ºC Warranty Life time warranty ...

Страница 8: ...oduct specifications and R TTE Directive of the European Union Safety EN60065 resp EN 60950 EMC EN55103 1 resp EN55103 2 Radio EN 301 489 1 301 489 17 EN 300 328 1 EN 300 328 2 Bratislava 10 May 2011 Robert Sloboda Copyright 2018 SRS Group s r o Specifications subject to change without notice Document DST4WH_en_manual_M312 Version 1 0 Actual as of 25 October 2018 SRS Group s r o Rybnicna 36 D 831 ...

Отзывы: