1. General information

 

1.1 Product overview and features

 

HF  series  is  a  new  all-in-one  hybrid  solar  charge  inverter,  which  integrates  solar  energy  storage  & 
means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control 
algorithm,  it  has  high  response  speed,  high  reliability  and  high  industrial  standard.  Four  charging 
modes are optional,  i.e. Only  Solar, Mains  Priority, Solar  Priority and  Mains  & Solar hybrid charging; 
and two output modes are available, i.e. Inverter and Mains, to meet different application requirements. 
The  solar  charging  module  applies  the  latest  optimized  MPPT  technology  to  quickly  track  the 
maximum  power  point  of  the  PV  array  in  any  environment  and  obtain  the  maximum  energy  of  the 
solar panel in real time. 
Through a state of the art control algorithm, the AC-DC charging module realizes fully digital voltage 
and current double closed loop control, with high control precision in a small volume. Wide AC voltage 
input  range  and  complete  input/output  protections  are  designed  for  stable  and  reliable  battery 
charging and protection. 
Based  on  full-digital  intelligent  design,  the  DC-AC  inverter  module  employs  advanced  SPWM 
technology  and  outputs  pure  sine  wave  to  convert  DC  into  AC.  It  is  ideal  for  AC  loads  such  as 
household appliances, power tools, industrial equipment, and electronic audio and video equipment. 
The product comes with a segment LCD display design which allows real-time display of the operating 
data and status of the system. Comprehensive electronic protections keep the entire system safer and 
more stable. 

Features:

 

1.

 

Full digital voltage and current double closed loop control, advanced SPWM technology, output 

of pure sine wave. 

2.

 

Two output modes: mains bypass and inverter output; uninterrupted power supply. 

3.

 

Available in 4 charging modes: Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid     

charging.  

4.

 

Advanced MPPT technology with an efficiency of 99.9%. 

5.

 

Designed with a LCD screen and 3 LED indicators for dynamic display of system data and  

operating status. 

6.

 

ON/OFF rocker switch for AC output control. 

7.

 

Power saving mode available to reduce no-load loss. 

8.

 

Intelligent variable speed fan to efficiently dissipate heat and extend system life. 

9.

 

Lithium battery activation by PV solar or mains, allowing access of lead-acid battery and lithium  

battery. 

10.

 

360 ° all-round protection with a number of protection functions. 

11.

 

Complete protections, including short circuit protection, over voltage and under voltage  

protection, overload protection, reverse protection, etc. 

 
 

Содержание SR-HF2420S40-75

Страница 1: ...All in one solar charge inverter 1 All in one solar charger inverter User Manual Product models SR HF2420S40 75 SR HF2420S60 100 SR HF2420S80 145 SR HF2430S40 75 SR HF2430S60 100 SR HF2430S80 145...

Страница 2: ...mmable or explosive or heavily dusty areas The mains input and AC output are high voltage so please do not touch the wiring terminals The housing of the all in one solar charge inverter is hot when it...

Страница 3: ...ON AND WIRING 11 3 OPERATING MODES 17 3 1 CHARGING MODE 17 3 2 OUTPUT MODE 18 4 LCD SCREEN OPERATING INSTRUCTIONS 19 4 1 OPERATION AND DISPLAY PANEL 19 4 2 SETUP PARAMETERS DESCRIPTION 22 4 3 BATTERY...

Страница 4: ...ys advanced SPWM technology and outputs pure sine wave to convert DC into AC It is ideal for AC loads such as household appliances power tools industrial equipment and electronic audio and video equip...

Страница 5: ...to power the load while charging the battery If the mains or generator is not connected the system can also operate normally and the load is powered by the battery and PV module 3 Battery Provided to...

Страница 6: ...arance AC input port Battery port AC output port ON OFF rocker switch USB communication port PV port RS485 CAN communication port Touch button Dry node port LED Indicator Grounding screw hole LCD scre...

Страница 7: ...e been tightened and the wires are secured with ties to avoid looseness of connections caused by shaking of wires during mobile application The system connection wires are selected according to a curr...

Страница 8: ...current is constant when the PV modules are connected in series the short circuit current is the sum of the short circuit currents of all PV modules connected in parallel the short circuit current of...

Страница 9: ...0 145 6mm2 10AWG 30A 2P 40A Note There is already an appropriate circuit breaker at the Mains input wiring terminal so it is not necessary to add one more Recommended battery input wire diameter and s...

Страница 10: ...SR HF2430S40 75 6mm2 10AW 13A 30A 2P 40A SR HF2430S60 100 6mm2 10AW 13A 30A 2P 40A SR HF2430S80 145 6mm2 10AW 13A 30A 2P 40A Note The wiring diameter is for reference only If the distance between the...

Страница 11: ...ne solar charge inverter ensure that there is enough air flowing through the heat sink and space of at least 200m to the left and right air outlets of the inverter shall be left to ensure natural conv...

Страница 12: ...t the external circuit breaker and confirm that the wire used is thick enough Please refer to Section 2 2 Wiring Specifications and Circuit Breaker Selection Properly connect the AC input wire accordi...

Страница 13: ...e first and then the live wire and the neutral wire The ground wire is connected to the grounding screw hole on the cabinet through the O type terminal Ground L Live N Neutral Note The grounding wire...

Страница 14: ...egative pole BAT wiring method Prior to wiring disconnect the external circuit breaker and confirm that the wire used is thick enough Please refer to Section 2 2 Wiring Specifications and Circuit Brea...

Страница 15: ...t be installed at the battery terminal Refer to Section 2 2 Wiring Specifications and Circuit Breaker Selection to select a right circuit breaker Before wiring be sure to disconnect the circuit breake...

Страница 16: ...ns Finally turn on AC loads one by one as the AC output is normal to avoid a protection action caused by a large momentary shock due to simultaneous turning on the loads simultaneously Now the machine...

Страница 17: ...y is preferentially used to charge the battery Only when the Mains fails the PV charging can be activated 3 Hybrid charging PV and mains hybrid charging PV MPPT charging is a priority and when PV ener...

Страница 18: ...ion Switch to mains supply when the PV charging fails This mode maximizes the use of solar energy while maintaining battery power suitable for use in the areas with relatively stable grid Mains priori...

Страница 19: ...ration buttons Operation buttons introduction Indicators introduction Function buttons Description SET Enter Exit Settings menu UP Previous choice DOWN Next choice ENT Confirm Enter Options under the...

Страница 20: ...hat the AC output is in an overload state Indicates that the machine has been connected to the battery indicates that the remaining battery is 0 24 indicates that the remaining battery is 25 49 indica...

Страница 21: ...verter circuit This icon is not displayed Display battery voltage battery charge total current mains charge power AC input voltage AC input frequency PV input voltage internal heat sink temperature so...

Страница 22: ...ency AC OUTPUT LOAD Hz AC output frequency 7 AC INPUT V AC input voltage AC OUTPUT LOAD A AC output load current 8 INPUT V For maintain OUTPUT LOAD KVA Load apparent power 9 INV TEMP AC charge or batt...

Страница 23: ...et through this menu The default output frequency of the 230V machine is 50HZ and the 120V machine 60HZ 02 60 0 03 AC Input Voltage Range 03 APL Wide mains input voltage range of 230V machine 90 280V...

Страница 24: ...charger PV charger Setting range 0 140A 08 Battery Type 08 USE User defined all battery parameters can be set 08 SLd Sealed lead acid battery constant voltage charge voltage 28 8V floating charge vol...

Страница 25: ...t delay the time set by parameter 13 and turn off inverter output Setting range is 20V 24V with a step of 0 2V It is valid for user defined battery and lithium battery 13 Battery over discharge delay...

Страница 26: ...attery and sealed lead acid battery 20 Battery equalization interval 20 30 default Equalizing charge derating time 0 30days with a step of 1 day valid for vented lead acid battery and sealed lead acid...

Страница 27: ...art when the temperature drops 25 Alarm enable 25 DIS Alarm is disabled 25 ENA default Alarm is enabled 26 Beeps while primary source is interrupted 26 DIS Alarm beep is disabled when the status of th...

Страница 28: ...ble 28 4V Adjustable 31 8V Adjustable 27 6V Adjustable 18 30V Adjustable Undervoltage alarm voltage 22V 22V 22V 21 6V Adjustable 24 8V Adjustable 27 8V Adjustable 22 4V Adjustable 18 30V Adjustable Lo...

Страница 29: ...ons It allows direct communication with the optional host computer stored on the CD ROM developed by our company through this port and enables monitoring of the equipment running status and setting of...

Страница 30: ...aches the overvoltage disconnection point the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged 6 Battery low voltage prote...

Страница 31: ...ver current protection When the discharge output current of the battery is greater than the maximum value and lasts for 1 minute the AC input would switched to load 14 Battery input protection When th...

Страница 32: ...age software protection 09 PvVoltHigh No PV overvoltage protection 10 PvBuckOCSw No Buck overcurrent software protection 11 PvBuckOCHw No Buck overcurrent hardware protection 12 bLineLoss No Mains pow...

Страница 33: ...ltage Fan failure Check if the fan is not turning or blocked by foreign object Heat sink over temperature protection When the temperature of the device is cooled below the recovery temperature normal...

Страница 34: ...high temperature or burning discoloration and tighten the screws 5 Check for dirt nesting insects and corrosion and clean up as required 6 If the arrester has failed replace in time to prevent lightn...

Страница 35: ...equency Range 47 0 3Hz 55 0 3Hz 50Hz 57 0 3Hz 65 0 3Hz 60Hz Overload shor t circuit protection Circuit breaker Efficiency 95 Conversion time bypass and inverter 10ms typical AC reverse protection Avai...

Страница 36: ...larm overvoltage recovery settable on LCD screen Power saving mode Load 50W AC charging Battery type Lead acid or lithium battery Maximum charge current can be set 0 60A 0 80A Charge current error 5Ad...

Страница 37: ...ations AC charger PV charger Max charger current can be set 0 100A 0 120A 0 140A 0 120A 0 140A 0 140A Certified specifications Certification CE EN62109 1 EMC certification level EN61000 C2 Operating t...