All-in-one solar charge inverter V7.0 1
All-in-one solar charger inverter
User Manual
Product models:
HF2420U60-100 | HF2430U60-100
Страница 1: ...All in one solar charge inverter V7 0 1 All in one solar charger inverter User Manual Product models HF2420U60 100 HF2430U60 100...
Страница 2: ...flammable or explosive or heavily dusty areas The mains input and AC output are high voltage so please do not touch the wiring terminals The housing of the all in one solar charge inverter is hot when...
Страница 3: ...9 2 3 INSTALLATION AND WIRING 11 3 OPERATING MODES 17 3 1 CHARGING MODE 17 3 2 OUTPUT MODE 18 4 LCD SCREEN OPERATING INSTRUCTIONS 19 4 1 OPERATION AND DISPLAY PANEL 19 4 2 SETUP PARAMETERS DESCRIPTIO...
Страница 4: ...loys advanced SPWM technology and outputs pure sine wave to convert DC into AC It is ideal for AC loads such as household appliances power tools industrial equipment and electronic audio and video equ...
Страница 5: ...ut to power the load while charging the battery If the mains or generator is not connected the system can also operate normally and the load is powered by the battery and PV module 3 Battery Provided...
Страница 6: ...Appearance AC input port Cooling fan AC output port Battery port USB communication port ON OFF rocker switch RS485 communication port PV port Dry node port Touch button Grounding screw hole LED Indic...
Страница 7: ...All in one solar charge inverter V7 0 7 1 4Dimension drawing...
Страница 8: ...have been tightened and the wires are secured with ties to avoid looseness of connections caused by shaking of wires during mobile application The system connection wires are selected according to a c...
Страница 9: ...t circuit currents of all PV modules connected in parallel the short circuit current of the PV array shall not exceed the maximum input current Refer to the table below for PV input wire diameter and...
Страница 10: ...ed inverter AC output current Maximum bypass output current Recommended air switch or circuit breaker type HF2420U60 100 8mm2 8AWG 16 7A 40A 2P 63A HF2430U60 100 8mm2 8AWG 25A 40A 2P 63A Note The wiri...
Страница 11: ...n one solar charge inverter ensure that there is enough air flowing through the heat sink and space of at least 200m to the left and right air outlets of the inverter shall be left to ensure natural c...
Страница 12: ...nect the external circuit breaker and confirm that the wire used is thick enough Please refer to Section 2 2 Wiring Specifications and Circuit Breaker Selection Properly connect the AC input wire acco...
Страница 13: ...ire first and then the live wire and the neutral wire The ground wire is connected to the grounding screw hole on the cabinet through the O type terminal Ground L Live N Neutral Note The grounding wir...
Страница 14: ...t negative pole BAT wiring method Prior to wiring disconnect the external circuit breaker and confirm that the wire used is thick enough Please refer to Section 2 2 Wiring Specifications and Circuit B...
Страница 15: ...ust be installed at the battery terminal Refer to Section 2 2 Wiring Specifications and Circuit Breaker Selection to select a right circuit breaker Before wiring be sure to disconnect the circuit brea...
Страница 16: ...ains Finally turn on AC loads one by one as the AC output is normal to avoid a protection action caused by a large momentary shock due to simultaneous turning on the loads simultaneously Now the machi...
Страница 17: ...pply is preferentially used to charge the battery Only when the Mains fails the PV charging can be activated 3 Hybrid charging PV and mains hybrid charging PV MPPT charging is a priority and when PV e...
Страница 18: ...ns power for charging and power supply Then the unit is equivalent to a backup UPS suitable for areas with unstable grid Switching does not affect PV charging Inverter priority mode Switch to mains su...
Страница 19: ...peration buttons Operation buttons introduction Indicators introduction Function buttons Description SET Enter Exit Settings menu UP Previous choice DOWN Next choice ENT Confirm Enter Options under th...
Страница 20: ...s that the AC output is in an overload state Indicates that the machine has been connected to the battery indicates that the remaining battery is 0 24 indicates that the remaining battery is 25 49 ind...
Страница 21: ...inverter circuit This icon is not displayed Display battery voltage battery charge total current mains charge power AC input voltage AC input frequency PV input voltage internal heat sink temperature...
Страница 22: ...INPUT V PV input voltage PV OUTPUT A PV output current 4 INPUT BATT A Input battery current OUTPUT BATT A Battery output current 5 INPUT BATT KW Battery input power OUTPUT BATT KW Battery output powe...
Страница 23: ...Mains when the PV fails or the battery is lower than the set value of parameter 04 01 UTI default Mains priority mode switching to inverter only when the mains fails 01 SBU Inverter priority mode swit...
Страница 24: ...the PV energy is insufficient the Mains charging supplements When the PV energy is sufficient the Mains charging stops Note Only when the Mains bypass output is loaded the PV charging and the mains ch...
Страница 25: ...g which means the maximum charging time to reach the set voltage of parameter 09 during constant voltage charging The setting range is 5min 900min with a step of 5 minutes It is valid for user defined...
Страница 26: ...abled only valid for vented lead acid battery and sealed lead acid battery 17 Battery equalization voltage 17 29 2V default Equalizing charge voltage setting range 24V 29 2V with a step of 0 2V valid...
Страница 27: ...e times the machine will not restart 24 Restart when over temperature 24 DIS Automatic restart when over temperature is disabled If an over temperature shutdown occurs machine will not restart to turn...
Страница 28: ...voltage the battery voltage needs to recover more than this set value before the inverter starts the output 36 Max PV charger current 36 60A default Max PV charger current Setting range 0 60A 37 Batt...
Страница 29: ...ble Undervoltage alarm voltage 01 fault 22V 22V 22V 18 30V Adjustable Undervoltage alarm voltage recovery point 01 fault Undervoltage alarm voltage 0 4V Low voltage disconnection voltage 04 fault 21 0...
Страница 30: ...31 6V Adjustable 24 6V Adjustable 28 4V Adjustable 31 6V Adjustable Undervoltage alarm voltage 01 fault 23 4V Adjustable 26 8V Adjustable 21 6V Adjustable 24 8V Adjustable 27 8V Adjustable Undervoltag...
Страница 31: ...on with the optional host computer developed by our company through this port and enables monitoring of the equipment running status and setting of some parameters on the computer It also allows direc...
Страница 32: ...reaches the overvoltage disconnection point the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged 6 Battery low voltage pr...
Страница 33: ...over current protection When the discharge output current of the battery is greater than the maximum value and lasts for 1 minute the AC input would switched to load 14 Battery input protection When...
Страница 34: ...oltage software protection 09 PvVoltHigh No PV overvoltage protection 10 PvBuckOCSw No Buck overcurrent software protection 11 PvBuckOCHw No Buck overcurrent hardware protection 12 bLineLoss No Mains...
Страница 35: ...f the device is cooled below the recovery temperature normal charge and discharge control is resumed 13 14 Bypass overload protection inverter overload protection Reduce the use of power equipment Res...
Страница 36: ...of high temperature or burning discoloration and tighten the screws 5 Check for dirt nesting insects and corrosion and clean up as required 6 If the arrester has failed replace in time to prevent lig...
Страница 37: ...wave Rated output power VA 2000 3000 Rated output power W 2000 3000 Power factor 1 Rated output voltage Vac 120Vac Output voltage error 5 Output frequency range Hz 50Hz 0 3Hz 60Hz 0 3Hz Maximum Effic...
Страница 38: ...Maximum output power 1400W PV charging current range can be set 0 60A Charging short circuit protection Blown fuse Wiring protection Reverse polarity protection Hybrid charging Max charger current spe...