GEN.0000000003161 REV A
10
SERviCE inSTRuCTionS (ConTinuEd)
Turn the Beginning Stroke Rebound and the
4.
Low Speed Compression
(R2C only)
adjusters
clockwise, until they stop. Use a 2.5 mm hex
to turn the Ending Stroke Rebound adjuster
clockwise until it stops.
Count each detent click as you turn the adjuster
and record the number of clicks to assist with
post-service set-up.
AiR CAn REMovAL (RouTinE SERviCE)
Remove the air can valve cap. Use a small hex or
5.
pick to depress the Schrader valve and release
all air pressure from the air can. Use a Schrader
valve tool to remove the valve core.
CAuTion
failure to remove all air pressure can lead
to personal injury during air can
disassembly.
Use a T10 TORX TORX
6.
®
to remove the air cap
from the IFP (Internal Floating Piston) reservoir.
Use a small hex or pick to depress the Schrader
valve and release all air pressure from the IFP
reservoir. Use a Schrader valve tool to remove
the Schrader valve core.
CAuTion
failure to remove all air pressure can lead
to personal injury during ifp reservoir
disassembly.
Use a 2.5 mm hex to remove the rebound
7.
adjuster knob bolt. Remove the rebound adjuster
knob from the shaft eyelet.
Insert the tips of the spanner tool into the
8.
holes of air can retaining ring, which is located
between the air can and shaft eyelet. Clamp the
shock rebound eyelet between the soft jaws of a
vise, leaving just enough room for the spanner to
rotate, but not come out of the retaining ring.
5
4
6
7
8