35
Charger Damper Bleed
2 0 0 H o u r S e r v i c e
C h a r g e r D a m p e r B l e e d
RCT3:
Use small retaining ring pliers to remove the retaining ring from
the low speed compression adjuster.
RC:
Use small retaining ring pliers to remove the retaining ring from the
bleed plug.
RCT3:
Use needle-nose pliers to remove the low speed compression
adjuster from the compression top cap.
RC:
Use needle-nose pliers to remove the bleed plug from the
compression adjuster.
1
RCT3
RC
2
RCT3
RC