Reservoir Cap Installation
R e s e r v o i r C a p I n s t a l l a t i o n
Press the bladder into the reservoir cap, make sure the bladder is
properly seated into the reservoir cap. The bladder should be flush
with the cap.
Insert the reservoir cap/bladder assembly onto the lever body.
Install the detent ball followed by the detent spring into the lever body
reservoir hole closest to the lever blade.
Use a torque wrench and a T10 TORX bit socket to tighten each
reservoir cap bolt to 1.2 N·m (10.5 in-lb).
1
2
3
4
T10
1.2 N•m (10.5 in-lb)
22 mm