SR Scales SR411i Скачать руководство пользователя страница 14

Model SR411

i

 Patient Floor Scale 

Operating and Service Manual 
Part No. MAN411

i

_MICROBAN_200610 

 

Page 14 of 16 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY 14150 

Tel: 716-693-5977    Fax: 716-693-5854    URL: 

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2020

 

S

Instruments, Inc. 

WARRANTY 

FOUR (4) YEAR LIMITED WARRANTY 

Each

  S

  system  is  manufactured  with  high  quality  components.    SR  Instruments,  Inc. 

warrants  that  all  new  equipment  will  be  free  from  defects  in  material  or  workmanship,  under 
normal  use  and  service,  for  a  period  of  four  (4)  years  from  the  date  of  purchase  by  the  original 
purchaser.    Normal  wear  and  tear,  injury  by  natural  forces,  user  neglect,  and  purposeful 
destruction are not covered by this warranty.  Warranty service must be performed by the factory 
or  an  authorized  repair  station.    Service  provided  on  equipment  returned  to  the  factory  or 
authorized repair station includes labor to replace defective parts.  Goods returned must be shipped 
with transportation and/or broker charges prepaid.  SR Instruments, Inc.’s obligation is limited to 
replacement  of  parts  that  have  been  so  returned  and  are  disclosed  to  SR  Instruments,  Inc.’s 
satisfaction  to  be  defective.    The  provisions  of  this  warranty  clause  are  in  lieu  of  all  other 
warranties,  expressed  or  implied,  and  of  all  other  obligations  or  liabilities  on  SR  Instruments, 
Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, 
Inc.  any  other  liabilities  in  connection  with  the  sale  of  said  articles.    In  no  event  shall  SR 
Instruments,  Inc.  be  liable  for  any  subsequent  or  special  damages.    Any  misuse,  improper 
installation, or tampering, shall void this warranty.  

DAMAGED SHIPMENTS 

Title  passes  to  purchaser  upon  delivery  to  Transportation  Company.    Purchaser  should  file  any 
claims for shortage or damage with  the delivery carrier and should refuse any shipment  that has 
obvious external damage.  

RETURN POLICY 

All products being returned to SR Instruments, Inc. require a Return Goods Authorization number 
(RGA).  To receive an RGA, call our Customer Service at 716-693-5977 ext 103 or toll-free in the 
USA and Canada at 800-654-6360 ext 103. 

When  inquiry  is  made,  please  supply  model  and  serial  numbers,  purchase  order  and  reason  for 
return.  

Generally,  deleted,  damaged,  and  outdated  merchandise  will  not  be  accepted  for  credit.    A 
minimum restocking charge of 15% will be assessed on return of current merchandise unless scale 
is returned because of SR error.  

No returns will be accepted after 30 days. 

All  returns  are  to  be  shipped  FREIGHT  PREPAID  to:    SR  Instruments,  Inc.,  600  Young  Street, 
Tonawanda, NY 14150. 

RESTOCKING FEE 

 

15% fee

 will be assessed on return of current merchandise 

 

No fees

 will be charged if the scale is returned because of an error on the part of SR 

Instruments, Inc. 

 

No returns 

accepted after 30 days

.

  

Содержание SR411i

Страница 1: ...ICROBAN_200610 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S Instruments Inc Operating and Service Manual Model SR411i Patient Floor Scale ...

Страница 2: ... Inc TABLE OF CONTENTS PACKING CHECKLIST MODEL SR411I 3 ASSEMBLY 3 SYSTEM DESCRIPTION AND INTENDED USE 4 MICROBAN ANTIMICROBIAL PROTECTION 4 STORAGE AND TRANSPORTATION 4 CLEANING AND DISINFECTING 5 SPECIFICATIONS 6 BUTTON FUNCTIONS 7 BASIC SYSTEM OPERATION 8 THEORY OF OPERATION 9 CALIBRATION 10 TROUBLESHOOTING 13 WARRANTY 14 DISPLAY MOUNTING TEMPLATE 15 TABLE OF FIGURES Figure 1 SR411i Button Labe...

Страница 3: ...ed by qualified personnel The mounting hardware provided will cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes are spaced 2 5 on center apart using the template provided on page 15 C Drill the two 2 pilot holes no larger than diameter in the locations marked Install the two 2 self drilling screw ...

Страница 4: ...ograms INTENDED USE The SR411i Patient Floor Scale is a unique lightweight low profile stand on scale system for weighing ambulatory patients The wide platform is designed to easily accommodate larger patients The SR411i Patient Floor Scale is a preferred means of gathering patient weight data of patients weighing up to 880 pounds 400 kilograms MICROBAN ANTIMICROBIAL PROTECTION Microban antimicrob...

Страница 5: ...areas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectants Disinfectant solutions with 1 sodium hypochlorite or 70 isopropyl alcohol are suitable for display user interface and other scale contact surfaces After disinfecting use a soft cloth dampen...

Страница 6: ...lution for calibrated range AUTO ZERO One button operation AUTO WEIGH Scale will automatically turn on and lock in on a stable weight AUTO POWER DOWN After 1 minute AVERAGING Automatic digital filter POWER SUPPLY Medical Grade AC Wall Power Supply CALIBRATION Calibration is traceable to NIST standards OPERATING CONDITIONS Normal operating conditions for this product Ambient Temperature Range 68 F ...

Страница 7: ...atient is in position on the scale the weight will be displayed NOTE When the system is zeroed the Hold Recall memory is erased LB KG BUTTON Patient weight data may be viewed in either pounds or kilograms Pressing the lb kg button allows the operator to toggle between the two readings HOLD RECALL BUTTON Scale will automatically lock a stable weight that is greater than five pounds and MEM will be ...

Страница 8: ...ternatively press the Zero Weigh button and wait for the display to indicate ZERO Release the Zero Weigh button and the display will read 0 0 Position the patient on the platform Weight will be displayed in a few seconds A stable weight will automatically be stored in memory STEP 3 To manually hold a weight reading at any time during the weighing process press the Hold Recall button NOTE When the ...

Страница 9: ...d by the operational amplifier The output of the operational amplifier is digitized by the analog to digital converter The converter integrates the analog signal onto the integrating capacitor over a short interval The integrating capacitor is then discharged at a rate proportional to the reference voltage applied to the converter The residual voltage on the integrating capacitor is then multiplie...

Страница 10: ...fied service personnel should perform this procedure Load cells have no user serviceable components and should not be tampered with for any reason Re calibration is generally not required but should be verified periodically to ensure accuracy The recommendation for calibration check is at least once every 12 months or as individual maintenance policy requires CAUTION The integrated circuits and se...

Страница 11: ...that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results CAL MENU data Displays saved calibration and model information unit Set the available units lb only kg only or selection of lb or kg with mode button sec Set Auto Power Down Timer between 15 and 900 seconds grav Set Gravitational Acceleration in m s2 Ful...

Страница 12: ...leration from the CAL menu by pressing the Left Button when the display shows grav b The display will show only the four digits to the right of the decimal point 9 XXXX c Set the local gravitational acceleration in m s2 by selecting the first digit and toggle through the digits using the Right Button until desired value is shown Press the Left Button and continue the same with the remaining digits...

Страница 13: ...aceable to NIST DO NOT USE barbells or uncalibrated weights The displayed calibrated weight should be within the Accuracy tolerance as listed in the SPECIFICATIONS table on page 5 a Select Two point calibration curve by pressing the Left Button when the display shows 2Pt b With no load applied zero the scale by pressing the Left Button when the display shows ZERO c Display will show FULL apply the...

Страница 14: ...r liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser up...

Страница 15: ...ay flat on a desk or end table If desired provisions for wall mount have been incorporated and can be accomplished in the manner described below A The display should be installed by qualified personnel The mounting hardware provided will cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes are spaced...

Страница 16: ...o MAN411i_MICROBAN_200610 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S By SInstruments Inc Precision Technology in Perfect Balance ...

Отзывы: