SR Instruments SRScales SRV947R Скачать руководство пользователя страница 8

Model SRV947R-BT 24 X 48 Remote Display Platform 
Operating and Service Manual 
Part No. MAN947R-BT_210610 

 

Page 8 of 18 

 
 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977     Fax: 716-693-5854    URL: 

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2021

 

S

Instruments, Inc. 

BASIC SYSTEM OPERATION  

 

TURNING SYSTEM ON 

Make  sure  the  scale  is  free  and  clear  of  any  obstructions  and  all  six  feet  are  touching  a  level 
surface.  Press the “

ZERO

” button and hold for 3 seconds.  The display will read “

ZERO

” then 

display “

0.0

” when system is ready for weighing.   

UNIT 

Press the “

MODE

” button to toggle between pounds or kilograms.  The system will remain in the 

same mode as last used unless manually changed. 

WEIGH

 

The “

WEIGH

” button is used to clear the “Recall” memory and start a new weighing cycle.   

HOLD/RECALL 

The “

HOLD/RECALL

” button is used to  “lock in” and store the weight currently displayed in 

system  memory.    With  no  weight  on  the  platform  pressing  the  button  again  will  recall  the  last 
stored weight and display it for 15 seconds. 

AUTOHOLD 

With  autohold  enabled,  when  the  system  detects  a  stable  weight,  that  value  will  be  stored  in 
system memory.  This value can later be recalled by pressing the “

HOLD/RECALL

” button with 

no weight on the platform. 

 

 

 

SCREEN DISPLAYED SYMBOLS           

 

 

 

 

 

Scale is zeroed and stabilized 

 

 

MEM 

Weight is locked in memory (next stable weight will override memory). 

 

 

 

 

 

Applied weight load has stabilized

 

 

 

 

 

 

 

Содержание SRScales SRV947R

Страница 1: ...610 Page 1 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc SRV947R BT REMO...

Страница 2: ...F CONTENTS TABLE OF FIGURES 2 PACKING CHECKLIST MODEL SRV947R BT 3 ASSEMBLY 3 SYSTEM DESCRIPTION AND INTENDED USE 4 STORAGE AND TRANSPORTATION 4 CLEANING AND DISINFECTING 5 SPECIFICATIONS 6 BUTTON FUN...

Страница 3: ...rsonnel The mounting hardware provided will cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes are...

Страница 4: ...patient s weight The patient s weight is displayed on an LCD screen With a push of a button weight data may be viewed in either pounds or kilograms INTENDED USE The SRV947R BT Portable Platform Scale...

Страница 5: ...act areas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available...

Страница 6: ...matically turn on and lock in on a stable weight AVERAGING Automatic digital filter POWER SUPPLY AC Wall Power Supply Medical Grade CALIBRATION Calibration is traceable to NIST standards OPERATING CON...

Страница 7: ...ts com Copyright 2021 SInstruments Inc MODE ZERO HOLD RECAL L BUTTON FUNCTIONS Figure 1 SRV947R BT Button Label The ZERO WEIGH button is used to clear the Recall memory and start a new weighing cycle...

Страница 8: ...en pounds or kilograms The system will remain in the same mode as last used unless manually changed WEIGH The WEIGH button is used to clear the Recall memory and start a new weighing cycle HOLD RECALL...

Страница 9: ...or remote wireless operation Use your Android device to display weight and control the SRV947R BT scale functions Figure 2 Ensure your remote display indicates CONNECTED before use The WEIGH button wi...

Страница 10: ...lified by the operational amplifier The output of the operational amplifier is digitized by the analog to digital converter The converter integrates the analog signal onto the integrating capacitor ov...

Страница 11: ...semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times IMPORTANT CALIBRATION CHECK Qualified service person...

Страница 12: ...r a parameter saved NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results CAL MENU data Displays...

Страница 13: ...the digits using the Right Button until desired value is shown Press the Left Button and continue the same with the remaining digits d Press the Left Button to save or Right Button to toggle to quit S...

Страница 14: ...Press the Left Button again to save and the display will show SAV d Calibrate using the Three Point Calibration Curve zero half scale and full scale NOTE The scale can also be calibrated with a Two p...

Страница 15: ...ECTIVE ACTION Weight reading is much lower than expected Check that the platform is clean underneath stand on each of the four corners to see if one corner is not weighing correctly System fails to pe...

Страница 16: ...rm Operating and Service Manual Part No MAN947R BT_210610 Page 16 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstrume...

Страница 17: ...ay lay flat on a desk or end table If desired provisions for wall mount have been incorporated and can be accomplished in the manner described below A The display should be installed by qualified pers...

Страница 18: ...ual Part No MAN947R BT_210610 Page 18 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInst...

Отзывы: