SR Instruments SRScales SRV945 Скачать руководство пользователя страница 3

Model SRV949 24 X 60 Platform Scale 
Operating and Service Manual 
Part No.:  MAN949_170724 

 

Page 3 of 14 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel:  716-693-5977     Fax:  716-693-5854    URL:  

www.srscales.com

 

email:  

[email protected]

        

Copyright 

2017

 

Instruments, Inc. 

 

PACKING CHECKLIST – Model SRV949 

Portable Platform Scale 

 

 

 

DESCRIPTION 

QUANTITY 

 

PORTABLE PLATFORM SCALE  

1 ea 

 

AA 1.5-VOLT ALKALINE BATTERIES 

6 ea 

 

CALIBRATION CERTIFICATE 

1 ea 

 

WARRANTY CARD 

1 ea 

 

MANUAL 

1 ea 

Содержание SRScales SRV945

Страница 1: ..._170724 Page 1 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2017 S Instruments Inc S by S Ins...

Страница 2: ...IGURES 2 PACKING CHECKLIST MODEL SRV949 3 ASSEMBLY 4 SYSTEM DESCRIPTION AND INTENDED USE 5 MAINTENANCE AND CLEANING 6 STORAGE AND TRANSPORTATION 6 SPECIFICATIONS 7 BUTTON FUNCTIONS 8 BASIC SYSTEM OPER...

Страница 3: ...onawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2017 S Instruments Inc PACKING CHECKLIST Model SRV949 Portable Platform Scale DESCRIPTION...

Страница 4: ...srinstruments com Copyright 2017 S Instruments Inc ASSEMBLY To install included six 6 AA 1 5 volt alkaline batteries follow steps below STEP 1 Unlatch tab on the Battery Compartment cover on bottom o...

Страница 5: ...latest in microprocessor and load cell technology to provide accurate and repeatable weight data Six 6 identically matched transducers are strategically placed to ensure an accurate representation of...

Страница 6: ...oap and water is recommended for general cleaning and disinfecting STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the batteries To maintain...

Страница 7: ...of displayed resolution for calibrated range AUTO ZERO One button operation AUTO POWER DOWN Approximately 120 seconds AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA 1 5 volt alkaline batter...

Страница 8: ...is procedure The display will read 0 0 LB or KG The button also wakes up the display and shows the patient s weight if it should Auto Power Down before the weighing process is done HOLD RECALL The HOL...

Страница 9: ...ace remains active If scale shuts down press the ZERO WEIGH button once to wake display and take reading HOLD RECALL The scale display is designed to automatically lock the reading on the display and...

Страница 10: ...tton STEP 3 Place the first calibrated weight on the scale Wait for scale to stabilize note scale reading Remove weight STEP 4 Place second calibrated weight on scale Wait for scale to stabilize note...

Страница 11: ...ZERO WEIGH button to turn the scale on STEP 3 Press Lb Kg button and toggle to select lb STEP 4 Press the left button on rear of display Display will read CAL STEP 5 Toggle the ZERO WEIGH button to re...

Страница 12: ...TEP 11 When display reads SAVE press the HOLD RECALL button to cycle through Savd and return to CAL STEP 12 Calibration is completed Press the left button on rear of display to return to run mode Allo...

Страница 13: ...nc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments In...

Страница 14: ...art No MAN949_170724 Page 14 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2017 S Instruments...

Отзывы: