Model SRV714 Series
Operating and Service Manual
Part No. MAN714_200601
Page 8 of 14
S
Instruments, Inc.
,
600 Young Street, Tonawanda, NY 14150
Tel: 716-693-5977 Fax: 716-693-5854 URL:
email:
Copyright 2020
S
Instruments, Inc.
SPECIFICATIONS
MAXIMUM WEIGHT
CAPACITY
15,000 lb. / 6800 kg. (Minimum 10 lb.)
PLATFORM SIZE
47 in x 95 3/8 in x 6 in
119 cm x 242 cm x 15 cm
DISPLAY TYPE
LCD
DISPLAY RESOLUTION
5 lb / 2 kg
ACCURACY
1% +/- 1 digits of displayed resolution for calibrated
range
AUTO ZERO
One button operation
STABILIZATION TIME
Five (5) seconds
AUTO POWER DOWN
After ten (10) minutes
BLUETOOTH ON-TIME
10 minutes from last button press
AVERAGING
Automatic digital filter
POWER SUPPLY
Six (6) “D” cell batteries
CALIBRATION
Calibration is traceable to NIST standards
OPERATING CONDITIONS
Normal operating conditions for this product: Ambient
Relative Humidity Range: 0% to 85%
Temperature Range: 40
F to 95
F (5
C to 35
C)
Avoid exposure to high-pressure water or steam.
TRANSPORTATION AND
STORAGE
Storage and transport conditions should not vary outside
the following conditions:
Relative Humidity 0% to 85%
Ambient Temperature 14
F to122
F (-10
C to +50
C)
Remove batteries if storing longer than three (3) months.
BLUETOOTH REQUIREMENTS
Refer to
further information. Minimum requirements for an OS
level of android device are listed at the google play store.