Model SRV715 Series
Operating and Service Manual
Part No. MAN715_190719
Page 7 of 16
S
Instruments, Inc.
,
600 Young Street, Tonawanda, NY 14150
Tel: 716-693-5977 Fax: 716-693-5854 URL:
email:
Copyright 2019
S
Instruments, Inc.
SPECIFICATIONS
MAXIMUM WEIGHT
CAPACITY
4,000 lb. / 1800 kg. (Minimum 10 lb.)
PLATFORM SIZE
48 in x 72 in x 4.25 in
122 cm x 183 cm x 11 cm
DISPLAY TYPE
LCD
DISPLAY RESOLUTION
1 lb / 0.5 kg
ACCURACY
0.2% +/- 1 digit of displayed resolution for calibrated
range
AUTO ZERO
One button operation
STABILIZATION TIME
Five (5) seconds
AUTO POWER DOWN
After ten (10) minutes
BLUETOOTH ON-TIME
10 minutes from last button press
AVERAGING
Automatic digital filter
POWER SUPPLY
Six (6) “AA” cell batteries
CALIBRATION
Calibration is traceable to NIST standards
OPERATING CONDITIONS
Normal operating conditions for this product: Ambient
Temperature Range: 40
F to 95
F (5
C to 35
C) Relative
Humidity Range: 0% to 85%.
Avoid exposure to high-pressure water or steam.
TRANSPORTATION AND
STORAGE
Storage and transport conditions should not vary outside
the following conditions: Relative Humidity 0% to 85%,
Ambient Temperature 14
F to122
F (-10
C to +50
C).
Remove batteries if storing longer than three (3) months.
BLUETOOTH REQUIREMENTS
further information. Minimum requirements for an OS
level of android device are listed at the Google Play
store.