SR Instruments SR Scales SRV415 Скачать руководство пользователя страница 1

Model SRV415 Multi-Purpose Floor Scale 
Service Manual 
Part No. MAN415

_

200714 

Page 1 of 14 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977   Fax: 716-693-5854   URL: 

www.srscales.com

 

email: 

[email protected]

   

 

Copyright 2020

 

S

Instruments, Inc. 

 
 

S

 

by 

Instruments, Inc.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operating and Service 

Manual 

 

Model SR

V415

 

Multi-Purpose Floor Scale 

Содержание SR Scales SRV415

Страница 1: ...4 Page 1 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S Instrument...

Страница 2: ...nc TABLE OF CONTENTS PACKING CHECKLIST MODEL SRV415 3 ASSEMBLY 3 SYSTEM DESCRIPTION AND INTENDED USE 4 STORAGE AND TRANSPORTATION 4 CLEANING AND DISINFECTING 5 SPECIFICATIONS 6 BUTTON FUNCTIONS 7 BASI...

Страница 3: ...otline at 1 800 654 6360 STEP 2 Unlatch tab on the battery compartment cover on bottom of scale Figure 1 Insert batteries according to instructions on the battery compartment holder Replace battery co...

Страница 4: ...ogy to provide accurate and repeatable weight data Four 4 identically matched transducers are strategically placed to ensure an accurate representation of weight Weight is displayed on a LCD screen Wi...

Страница 5: ...a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectants...

Страница 6: ...olution for calibrated range AUTO ZERO One button operation AUTO POWER DOWN Approximately 60 seconds 1 minute AVERAGING Automatic digital filter POWER SUPPLY Six 6 AA 1 5 volt alkaline batteries CALIB...

Страница 7: ...to memory To recall last weight reading press Hold Recall button once scale has shut down LB KG Weight data may be viewed in either pounds or kilograms Pressing the lb kg button allows the operator to...

Страница 8: ...reading in memory once the weight is stable If scale cannot lock in reading due to movement press the Hold Recall button to automatically lock the display and store the reading To return to WEIGH mode...

Страница 9: ...desired then it will need to be re set Both procedures are found next IMPORTANT CALIBRATION CHECK Qualified service personnel only should perform this procedure Load cells have no user serviceable co...

Страница 10: ...2 Full Applied calibrated mass at full scale Half Used only with three point calibration curve Applies calibrated mass at a second point between zero and full scale usually at half zero No calibrated...

Страница 11: ...display will show only the five digits XXXX X with the thousand place flashing 1 Select past to the next digit by pressing the Left Button c Once in the hundreds place set the full scale value maximum...

Страница 12: ...ply the predetermined full scale value on the scale and press the Left Button e Display will show SAVE press the Left Button to save display will show SAV d or Right Button to toggle to quit Select qu...

Страница 13: ...es on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event s...

Страница 14: ...o MAN415_200714 Page 14 of 14 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S...

Отзывы: