CFB/EN (1808) 2.4
Disassembly and assembly
25
CombiFlexBloc
7 Disassembly and assembly
7.1
Precautionary measures
Take adequate measures to avoid that the motor is started while you are
working on the pump. This is especially important for electric motors with
remote control:
• Switch the operating switch near the pump (if available) to "OFF".
• Switch off the pump switch on the switchboard.
• If necessary remove the fuses.
• Hang a danger board near the switchboard cabinet.
7.2
Special tools
Assembly and disassembly work requires no special tools. However, such tools can
make certain jobs easier, for instance replacing the shaft seal. If such is the case it will be
indicated in the text.
7.3
Liquid draining
!
Make sure no liquid gets into the environment!
Before starting any disassembly the pump should be drained through the drain plug
(0320). If possible, also drain the suction bend to a certain extent (if provided with a
suction bend (0400) through drain plug (0350)). Wherever necessary, first close
possible valves in the suction and delivery pipe. If the pump processes harmful liquids,
take the following precautions:
1 Wear protective gloves, shoes, glasses, etc.
2 Flush the pump properly.
3 Make sure no liquid gets into the environment.
4 Refit the drain plug.
Содержание CombiFlexBloc Series
Страница 2: ......
Страница 4: ...2 EC EN 1712 6 0...
Страница 6: ...4 INT EN 1512 1 2...
Страница 18: ...16 General CFB EN 1808 2 4...
Страница 52: ...50 Dimensions CFB EN 1808 2 4...
Страница 54: ...52 Parts CFB EN 1808 2 4 9 2 Pump construction K1 9 2 1 Sectional drawing M0 Figure 22 Sectional drawing M0...
Страница 78: ...76 ORDFORM 1512 3 3 EN...