CFB/EN (1808) 2.4
General
15
CombiFlexBloc
2.5.5
Foot pads
The foot pads consist of profiled steel elements or of a tubular construction with an
opening for the passage of the suction bend
2.6
Application area
The application area globally looks as follows:,
However, the maximum allowable pressures and temperatures depend strongly on the
selected materials and components. Also working conditions may cause differences. For
more detailed information see chapter 10 "Technical data".
2.7
Re-use
The pump may only be used for other applications after prior consultation with
SPXFLOW or your supplier. Since the lastly pumped medium is not always known, the
following instructions should be observed:
1 Flush the pump properly.
2 Make sure the flushing liquid is discharged safely (environment!)
Take adequate precautions and use the appropriate personal protection
means like rubber gloves and spectacles!
2.8
Scrapping
If it has been decided to scrap a pump, the same flushing procedure as described for
Re-use should be followed.
Table 1: Application area.
Maximum value
Capacity
720 m
3
/h
Discharge head
105 m
System pressure
10 bar
Temperature
110 °C