6
APV_VRA_UK-3_032017.indd
Vacuum Valve
DELTA VRA 11
Instruction Manual: UK – rev. 3
APV
UK
10. Dimensions / Weights
DN
dimensions in mm
weight
A
Ø C
Ø D
kg
50
310
50
127
3,3
100
340
100
198
5,4
150
420
150
277
8,4
11. Technical Data
max. line pressure
10 bar
max. operating temperature
135° C EPDM,
*VMQ,
*FPM
short-term load
140° C EPDM,
*VMQ,
*FPM
*(no
steam)
response pressure
40 mm WC standard
adjustable from 35 mm WS
to
60
mm
WC.
(change of response pressure, see chapter 12.5)
flow rates (m³/h) at a negative pressure of
100 mm WC
200 mm WC
DN 50
39
80
DN 100
215
317
DN 150
324
943
A
Ø D
Ø C