background image

12

APV_SI2_UK-6_012019.indd

UK

Safety Valve

DELTA SI2

Instruction manual UK-rev. 6

APV

12.   Trouble Shooting

Failure

Remedy

Operating position: closed

Leakage at the discharge side.

Replace seat ring (3).

Check control of seat lift actuator.

Leakage between housing flange and

flange of spring cylinder.

Check housing seal (7) and shaft seal (34),

replace damaged seal.

Seat lift cylinder does not work

Check whether ring (19, 41) is stuck.

Replace piston seal (15).

Valve feedback does not work or is unprecise.

Carry out fine adjustment.

Check whether ring (19, 41) is stuck.

The item numbers comply with the spare parts lists. The 

replacement of seals must be carried out

according to Service Instructions (see chapter 11).

!  If damaged seals are replaced, generally all seals should be 

changed. Complete seal kits for the valve service are available 

(see spare parts lists).

13.   Spare Parts Lists

The reference numbers of the spare parts for the different valve 

designs and sizes are included in the attached spare parts drawings 

with corresponding lists.

Please indicate the following data to place an order for spare parts:

- number of required parts

- reference number

- designation.

Data are subject to change

Содержание APV DELTA SI2

Страница 1: ...APV DELTA SI2 SAFETY VALVE FORM NO H170706 REVISION UK 6 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT INSTRUCTION MANUAL...

Страница 2: ......

Страница 3: ...PR2 PRD2 SI2 UF R3 VRA H in the nominal diameters DN 10 150 ISO 1 2 4 and 1 Sh5 6 Sh5 and the valve manifolds installed thereof meet the requirements of the Directives 2006 42 EC superseding 89 392 EE...

Страница 4: ......

Страница 5: ...ights 5 8 Technical Data 6 7 8 1 General data 8 2 Compressed air quality 9 Materials 7 10 Maintenance 8 11 Service Instructions 9 11 11 1 Dismantling from the line system 11 2 Dismantling of internal...

Страница 6: ......

Страница 7: ...k of injury by sudden valve operation Observe Service Instructions to ensure safe maintenance ofthe valve Do not remove the lead seal malfunction of valve and loss of guarantee 3 Intended Use Mode of...

Страница 8: ...rd types Operating distance 5 mm diameter 1 mm length 30 mm If the customer decides to use a valve feedback other than APV type we cannot take over any liability for a faultless function Cleaning devi...

Страница 9: ...rd and is tested and adjusted accordingly The standard housing is equipped with groove flanges FN1B with inspection certificate APZ 3 1 The appropriate mating flanges FG1B are available The response p...

Страница 10: ...ghts dimensions in mm DN A B C D E F G L weights in kg 25 241 96 50 26 129 96 131 468 4 8 40 273 109 66 38 129 109 131 513 6 2 50 312 122 81 50 129 122 131 565 8 7 65 356 135 100 66 129 135 131 622 13...

Страница 11: ...VMQ FPM no steam discharge figure 0 49 for liquids 0 44 for steams and gases air connection for hose 6 x 1 pneumatic air pressure for seat lift actuator max 10 bar min 6 bar To provide for a faultless...

Страница 12: ...dew point temperature 20 C For installations at lower temperatures or at higher altitudes additional measures must be considererd to reduce the pressure dew point accordingly Content of oil quality c...

Страница 13: ...lete seal kits according to spare parts list All seals must be provided with a thin layer of grease before their installation Recommentation APV assembly grease for EPDM FPM and HNBR 750 g tin ref No...

Страница 14: ...housing cover 8 2 Release the hexagon screws 37 and the washers 36 at the guide 6 and take out the complete valve seat 3 Separate the guide 6 from the seat 2 4 Separate the cap 4 from the seat 2 5 Sea...

Страница 15: ...ing ring 35 in the housing cover 8 2 Press the sliding ring 34 into reniform shape and put it into the groove of the housing cover onto the o ring fig 1 3 Slide the housing cover 8 onto the pressure r...

Страница 16: ...y slight backward movement of the proximity switch the shift point can be adjusted more precisely if necessary Observe the luminous diodes in the feedback during the adjustment Fix the feedback with c...

Страница 17: ...cise Carry out fine adjustment Check whether ring 19 41 is stuck The item numbers comply with the spare parts lists The replacement of seals must be carried out according to Service Instructions see c...

Страница 18: ......

Страница 19: ...um Blatt 1 von SPX Flow Technology Rosista GmbH D 59425 Unna Germany Weitergabe sowie Vervielf ltigung dieser Unterlage Verwertung und Mitteilung ihres Inhalts nicht gestattet soweit nicht schriftlich...

Страница 20: ...627 42 21 87 628 42 31B 21 85 628 47 H143241 ref no 21 87 629 42 H143247 58 33 546 73 58 33 193 33 58 33 546 13 58 33 692 33 58 33 742 33 H172126 58 33 642 33 H170074 H172125 31B 15 00 530 42 WS Nr 5...

Страница 21: ...102 item Menge quantity Beschreibung 12 1 Piston seal description 1 Unterteil f r Anl ftzylinder Federeinstellschraube Setting screw for spring Base for seat lift actuator Deckel f r Anl ftzylinder C...

Страница 22: ...rew 38 4 Skt Schraube DIN EN 24017 3 4301 41 1 1 4301 Lock washer 40 2 Sicherungsscheibe 1 4122 42 1 43 1 SPX Firmen Logo Klebefolie transparent SPX company logo Vestamit L1930 schwarz Haube f r Handa...

Страница 23: ...t L1930 schwarz 15 31 100 93 H140127 Pos 3 5 7 26 34 35 36 nur im kompletten Dichtungssatz erh ltlich Item 3 5 7 26 34 35 36 available as complete seal kits only Dichtungssatz FPM 58 34 650 00 58 34 6...

Страница 24: ...t to incorporate the latest design and material changes without notice or obligation Design features materials of construction and dimensional data as described in this manual are provided for your in...

Отзывы: