SPX PE17 Series Скачать руководство пользователя страница 1

HYDRAULIC PUMP

Max. Capacity: See Pump Data Plate

Definition: A hydraulic pump delivers hydraulic fluid under
pressure through the use of compressed air, an electric motor,
or a gas engine as a power source.

Form No. 102875

Operating Instructions for:

Electric Motor Powered Pumps
Gas Engine Powered Pumps
Rotary Air Motor Powered Pumps

(As listed in EC Declaration)

dB(A) at

Idle and

Pump

kw

700 Bar

PE8 Series

.37

67/81

PE17 Series

.37

67/81

PA17 Series

1.12

85/90

PE30 Series

.74

87/82

PG30 Series

1.49

84/96

PE46 Series

1.12

77/81

PA46 Series

2.24

85/90

PE55 Series

.84

87/86

PA55 Series

2.24

87/88

PG55 Series

2.98

75/87

PR10 Series

.19

65/72

PG18 Series

1.86

81/96

PG120 Series

4.1

85/95

PQ120 Series

2.24

73/78

PG400 Series

14.9

N/A

66262

2.24

N/A

UNIVERSAL

MOTOR

TEFC MOTOR

AIR MOTOR

DC MOTOR

RESERVOIR

GASOLINE

ENGINE

NOTE:

For a detailed parts list or to locate a Power Team Authorized
Hydraulic Service Center, contact your nearest Power Team facility.
A list of all Power Team facilities is located at the end of this
document.

Carefully inspect the pump upon arrival. The carrier, not the
manufacturer, is responsible for any damage resulting from
shipment.

The customer can choose from a variety of motors, controls,
reservoirs, and other options. These instructions will include
directions for options that your particular pump may not have.

Do not change motors without consulting the pump manufacturer's
Technical Services Department.

Q U

A R

T E

R  

H O

R S

E

®

12 VDC

Sheet No.

1 of 8

Rev 10

Date: 02 Mar 2005

© 2005 SPX Corporation

Tech. Services: (800) 477-8326

Fax: (800) 765-8326

Order Entry: (800) 541-1418

Fax: (800) 288-7031

SPX Corporation
5885 11th Street
Rockford, IL 61109-3699 USA

Internet Address: 

http://www.powerteam.com

®

Содержание PE17 Series

Страница 1: ...OTOR TEFC MOTOR AIR MOTOR DC MOTOR RESERVOIR GASOLINE ENGINE NOTE For a detailed parts list or to locate a Power Team Authorized Hydraulic Service Center contact your nearest Power Team facility A lis...

Страница 2: ...ts Only qualified operators should install operate adjust maintain clean repair or transport this machinery These components are designed for general use in normal environments These components are no...

Страница 3: ...if improperly performed hazardous procedure Consult the manufacturer for specific information before attempting any rewiring All PE55 Series pump motors must be wired for clockwise CW rotation when v...

Страница 4: ...result in personal injury Never repair with tape Do not use the hose to move attached equipment Stress can damage the hose and possibly cause personal injury Hose material and coupler seals must be c...

Страница 5: ...ded Clean all hose ends couplers and union ends Connect all hose assemblies to the pump and cylinder Use an approved high grade pipe thread sealant to seal all hydraulic connections Tighten securely a...

Страница 6: ...be rewired TEFC and DC Motors See pump data plate for voltage frequency current and power specifications If rewired retesting may be required per local directives and standards PR10 series pump voltag...

Страница 7: ...ittings not supplied as shown in Figure 1 Air supply must be minimum 50 CFM 1 4 M3 min and 80 PSI 5 5 BAR with 100 PSI 7 BAR maximum 1 Place the valve in the neutral or hold position 2 Couple the air...

Страница 8: ...ylinder 3 When the cylinder has advanced to the desired position deactivate the switch or remote switch or turn the pump unit OFF or shift the valve to the center position The cylinder will HOLD press...

Страница 9: ...pump unit OFF or shift the valve to the HOLD position NOTE Non posi check valves will momentarily lose pressure when shifting to HOLD position See posi check valve section of this form 5 Retract the c...

Страница 10: ...zed Pressure to cylinder port A Cylinder port B to tank Solenoid B Energized Pressure to cylinder port B Cylinder port A to tank 9512 NOTE Pressure holds without loss when shifted from cylinder port t...

Страница 11: ...han the pressure regulating valve to work properly P T A B Gauge Gauge Single acting Spring Return Cylinder Either fluid port A or B must be plugged with a steel plug on the valve With port B plugged...

Страница 12: ...owever the inertia of the motor continues to deliver fluid for a brief period The pressure regulating valve bypasses this surplus hydraulic fluid preventing it from going into the system As a result t...

Страница 13: ...ts sealing surface Overtightening can cause pump damage on bladder equipped pumps 5 The frequency of fluid changes will depend upon the general working conditions severity of use and overall cleanline...

Страница 14: ...qualified personnel familiar with this equipment Use the proper gauges and equipment when trouble shooting NOTE For a detailed parts list or to locate a Power Team Authorized Hydraulic Service Center...

Страница 15: ...r under Set up Instructions section 2 Check quick disconnect couplings to cylinders to ensure that they are completely coupled Occasionally couplers have to be replaced because the ball check does not...

Страница 16: ...te gauge 2 Contact a Power Team Authorized Hydraulic Service Center PROBLEM CAUSE SOLUTION Pump will not build full pressure continued 5 Inadequate power supply 6 Leaking control valve or defective pu...

Отзывы: