CV/EN (1009) 5.3
Maintenance
33
CombiPrime V
5 Maintenance
5.1
Daily maintenance
Regularly check the outlet pressure.
No water should get into the terminal box of the electric motor when the
pump room is sprayed clean! Never spray water on hot pump parts! The
sudden cooling down may cause them to burst and hot water may flow out!
5.2
Service liquid
After the pump has been put into operation once, the working-liquid tank and the float-
controlled de-aerator don't have to be filled up again: there is constantly a sufficient
quantity of pumped liquid in the working-liquid tank and the float- controlled de-aerator.
5.3
Shaft sealing
5.3.1
Mechanical seal
A mechanical seal generally requires no maintenance, however,
it should never be
allowed to run dry
. If there are no problems, do not dismantle the mechanical seal. As
the seal faces have run in on one another dismantling usually implicates replacement of
the mechanical seal. If a mechanical seal shows any leakage it has to be replaced.
5.3.2
Lip seal
The lip seals generally require no maintenance. The lip seals run around stainless steel
shaft sleeves which are provided with a hard wearing layer. The space between the lip
seals is filled with grease when they are mounted, so as to limit wearing to a minimum.
When the lip seals are leaking they have to be replaced.
5.4
Lubrication of the bearings
The bearings have to be re-greased after every 1000 hours of operation. The bearings
are greased before delivery. In case the pump is overhauled, the bearings and the
bearing house have to be cleaned and provided with new grease. See paragraph 10.1
"Recommended greases" for recommended greases and quantities to be applied.
The bearings requires re-greasing after every 1000 hours of operation. The bearings are
filled with grease during assembly. In case the pump is overhauled, the bearing house
and the bearings have to be cleaned and provided with new grease. For recommended
greases see paragraph 10.1 "Recommended greases".
Содержание Johnson Pump CombiPrime V
Страница 3: ...2 EC EN 1001 5 1...
Страница 5: ...4 CV EN 1009 5 3...
Страница 9: ...8 CV EN 1009 5 3...
Страница 49: ...48 Disassembly and assembly CV EN 1009 5 3...
Страница 63: ...62 Dimensions CV EN 1009 5 3...
Страница 65: ...64 Parts CV EN 1009 5 3 9 2 Pump 9 2 1 Sectional drawing Figure 29 Sectional drawing...
Страница 81: ...80 Technical data CV EN 1009 5 3...
Страница 85: ...84 ORDFORM 0804 3 1 EN...