18
Installation
CV/EN (1009) 5.3
3.4
Mounting
3.4.1
Installation of a pump unit
Pump and motor shafts of complete pump units are adjusted perfectly in line in the
works.
1 In case of permanent arrangement place the base plate level on the foundation with
the aid of shims.
2 Carefully tighten the nuts on the foundation bolts.
3 Check the alignment of pump and motor shafts and if necessary realign, see
paragraph 3.4.3 "Alignment of the coupling".
3.4.2
Assembling a pump unit
If the pump and the electric motor still have to assembled, do the following:
1 Remove the front guards (0270). Check if there is a key in both shaft ends.
2 Clean the motor and pump shaft. Grease both shaft ends with mounting grease.
3 Mount the flattened coupling part on the pump shaft (2200). Keep the coupling part
in line with the pump shaft end and fasten the coupling with the locking screw.
4 Fix the other coupling half on the motor shaft.
5 Place the electric motor on the flange (0260). Secure the electric motor with bolts
(0850) and nuts (0851). Push the coupling half on the motor shaft upward.
➢
Wherever possible use a hoisting machine and the crane hooks on the electric motor.
6 Mount the distance sleeve on the lower coupling half.
7 Push the upper coupling half downward. For the correct distance between the
coupling halves, see figure 2 with the corresponding table. Then secure the coupling
half on the motor shaft.
8 Check whether the coupling can be turned by hand. Check the alignment, see
paragraph 3.4.3 "Alignment of the coupling".
9 Mount the guards.
Содержание Johnson Pump CombiPrime V
Страница 3: ...2 EC EN 1001 5 1...
Страница 5: ...4 CV EN 1009 5 3...
Страница 9: ...8 CV EN 1009 5 3...
Страница 49: ...48 Disassembly and assembly CV EN 1009 5 3...
Страница 63: ...62 Dimensions CV EN 1009 5 3...
Страница 65: ...64 Parts CV EN 1009 5 3 9 2 Pump 9 2 1 Sectional drawing Figure 29 Sectional drawing...
Страница 81: ...80 Technical data CV EN 1009 5 3...
Страница 85: ...84 ORDFORM 0804 3 1 EN...