— 17 —
6. CONTROLLER – TIMER BASED
This section provides connection, adjustment and operational
information for the Timer Based – Fixed Cycle Controller. Similar
information for the Level 1 – Fixed Cycle Controller and Level 2
Controller featuring the APSS, Automatic Purge Saving System, can
be found in Sections 7 and 8 respectively.
6.1 Reference Figures – Timer Based Controller
•
Figure 6-1, Front Panel Overlay – Timer Controller
•
Figure 6-2, Point-to-Point Diagram – Timer Controller
6.2 Connections – Timer Based Controller
See Figure 6-2, Point-to-Point Diagram for the location and function of
the various cable and cord connectors that are provided on the bottom
of the Timer Based enclosure.
6.2.1 Connections - Input Power
6.2.1.1 VAC Input Power Connections
Single-phase, alternating current (AC) input power connection of 100-
240 VAC / 1 ph / 50-60 Hz. can be made at terminals mounted within
the control enclosure. See reference figures for proper polarity.
Program Step
1
2
3
4
5
6
7
8
Left tower status
drying
drying
drying
drying
regen
regen
regen
regen
Right tower status
regen
regen
regen
regen
drying
drying
drying
drying
Left purge solenoid
off
off
off
off
off
off
on
off
Right purge solenoid
off
off
on
off
off
off
off
off
Left purge valve
closed
closed
closed
closed
closed
closed
open
closed
Right purge valve
closed
closed
open
closed
closed
closed
closed
closed
Table 6-1
Cycle Sequence Steps –Timer Based Controller
Dryer MOP
60 - 150 psig (4.1 - 10.3 barg)
ISO Class
2
Dew Point
-40°C
-40°F
Cycle Time (minutes)
10
Time
Time from start of cycle
(minutes:seconds)
t0
00:00
t1
00:02
t2
00:06
t3
04:12
t4
05:00
t5
05:02
t6
05:06
t7
09:12
t8
10:00
Reference Data
Purge time (min:sec)
04:12
Repress. time (min:sec)
00:48
Table 6-2
Fixed Cycle Timing –Timer Based Controller