flexitrax™ flexiprobe™ Operation Manual
5 System setup
109
5.4
Calibrate the equipment
flexiprobe™ 540c
Every time you power up the Controller, you will need to calibrate the pushrod reel to ensure that
camera distances are accurate. Briefly, after the setup wizard is complete:
1. Select the
reel type
.
In the Equipment settings menu, select the reel type currently attached to the controller. Then
select the
Continue
menu item.
2. The controller now displays an advisory reminding you to rewind the pushrod fully onto the reel (coiler).
Make sure the pushrod is layered evenly and correctly onto the reel
and
the end of the rod is level with
the rod guide.
3. Press the
Calibrate
button to calibrate the reel.
After calibrating the reel, press the
Back
button or Esc key to return to the controller home screen.
You can now use the Settings menus to configure the system; continue to section 5.5.
Note: For definitions of calibration and zero distance, see
section 1.2
flexitrax™ 550c
Every time you power up the Controller, you will need to confirm what equipment is connected to the
system.