3
Introduction
Power supply formulae:
●
V
ac
= 0.7 x V
DD
●
I
ac
= 1.7 x I
dc
●
Transformer VA needed = V
ac
x I
ac
●
Average current per diode = 0.5 I
dc
●
Diode reverse volts = 2 x V
ac
3 A fuse
V+
V-
ac in
24 V
60 Va
Idc
Iac
Vac
3000 µF
V
DD
-
+
Figure 1
Unregulated DC rectifier power supply example
V
DD
36
34
32
30
28
26
0 0.4 0.8 1.2 1.6 2.0 2.4 2.6
Amps
Average
Ripple
I
dc
Figure 2 Typical power supply performance
Figure 2 shows the dc output of a 60 W
non-regulated supply.
Fitting a larger filter capacitor will help
to reduce the ripple limits.
1.1.2 Output current and supply voltage
The 200XLV provides a maximum of ±2 A of continuous current, depending on the armature
(AV) and supply voltage (V
DD
).
It requires a supply of at least (8 V + AVmax) to deliver the maximum output current.
The supply voltage can be 12 to 48 V, ±25%, with an absolute maximum of 60 Vdc. NOTE: The
optimum supply is the lowest voltage to supply a fault-free operation.
The short-term current limit overload capability is 150% of the continuous current, for
example, 2 A continuous current, 3 A peak.