21
SHARK welded to the mast
11.4 Corrosion protection
All housing parts consist of a seawater-proof aluminum alloy and are additionally
treated with a powder coating (2-layer structure). If this layer is damaged, there is
a risk of corrosion. Please touch up with a suitable varnish.
11.5 Mast construction
The Shark S601 flange must be attached to the mast! Either with 2 screws (picture
1) or welded on (picture 2).
11.6 Electrical System
Please bring the wind generator to a standstill first so that all lines are free of
voltage.
Check all connection points for tight fit and corrosion. Correct any corrosion that
may have occurred and treat with contact spray. You should pay particular
attention to the battery connections. These are to be cleaned and treated with pole
grease. The battery must be checked and repaired according to the manufacturer's
instructions. If there are several batteries, you should also check for different
capacities (self-discharge). Only connect the same size (Ah) and the same aged
batteries in parallel!
SHARK attached with 2 screws