background image

www.teejet.com

INSTALLATION

Please read before installing this equipment. Failure to do so may void your 

warranty.

Installation

The 801 and 802 flow meters give the best accuracy when there is a smooth, 

unobstructed flow through it. To minimize turbulence, there should be at least 

12″/30cm of straight plumbing upstream from the flow meter and at least 

6″/15cm of straight plumbing downstream from the flow meter. Mount the flow 

meter in a location that physically protects it from damage and allows liquid to 

drain away after the sprayer is flushed and secured at the end of the operating 

day. A straight, vertical section of the main boom supply line is the ideal location 

for the flow meter.

Keep the flow meter from lying in a low section of the sprayer plumbing. 

This is particularly important in cold weather when water might freeze in the 

flow meter and cause damage to the unit. It is also important when applying 

chemical suspensions which may settle out and stall the flow meter turbine if 

they cannot drain away.

Before installing the flow meter insert, make sure there are no obstructions in 

the insert cavity. Clearance at the bottom of the cavity is very close and over 

compressing of foreign material in the cavity can cause damage to the flow 

meter body. For 801, turn the insert locking collar until it is hand tight. For 802 

install the flow meter insert until the pin openings are aligned. 

Prior to each day’s spraying, the flow meter should be inspected to ensure there 

are no leaks around the attachment fittings. At the end of the day, care should 

be taken to thoroughly flush the flow meter with clean water.

Make sure no water or sediment is trapped in the flow meter

The impeller type flow meters supplied by TeeJet Technologies are inherently 

rugged. However, continued use over time will eventually wear the internal 

bearings and shafts until the meter becomes inaccurate. Replacement kits are 

available to repair the flow meters. Contact your TeeJet Technologies dealer for 

these parts.

8 0 1 / 8 0 2   F LO W   M E T E R S

INSTALLATION, SPECIFICATION, AND WARRANTY INFORMATION

8 0 1   &   8 0 2   F L O W   M E T E R S

O-Ring

Bolt

Sensor

Hose Barb

Flow Meter Sensor

Main Flow Meter Body

Flanged

Clamp

>12"/30cm

> 6"/15cm

Main Product

 Pump

Bypass Line

Auto Range®

Valve   

Pump Discharge

Flow Meter

To Booms

NOTE: The Flow Meter 

must be mounted so that 

it will drain completely 

when the sprayer is not 

operating

Connector, Deutsch 3 Pos/Skts

Pin Out

Color

Function

A

Red

+4.5V to 16V

B

White

Signal

C

Black

Ground

Connector, Conxall 3 Pos/Pins

Pin Out

Color

Function

1

Black

Ground

2

White

Signal

3

Red

+5V

Отзывы: