background image

17

 

SECTION 8

 

SPARE PARTS 

 

 

Part Number

 

Description

 

1/4BBCV

-

SS10

 

CHECK VALVE, 303SS

 

23220

-

1/4FX1/4F

 

PLUG VALVE, 23220

-

1/4FX1/4F PLUG VALVE ASB.BRASS

 

AA10000

-

72440T

-

EPM8

 

Heated PulsaJet Spray Nozzle 

-

 Threaded Connection.

 

LS00LMT100

 

Switch, Point level sensor, high frequency capacitance, for water

-

based media

 

OR004061T162

 

O

-

ring, Square, Buna

-

N, 70 Duro

 

160TS16MV0001W5_SU01

 

Auto

-

Refill Level Sensor

 

PL00416TV

 

VENT, AIR, AUTOMATIC, 1/8" MALE NPT BRASS / BRASS, 115 PSI, 140°

-

 240°F

 

FT003133

-

JT_AC20

 

20 ft Jacketed Hose

 

PR00301DFW254D

 

Pressure, gauge, 0 

-

 60 psi, stainless steel connection and case, plastic lense, 

dry case 2

-

1/2" diameter dial, 1/4" NPT male connection, 200F max

 

PU00CRI12WASH1P

 

Pump, Centrifugal, 304SS wetted parts, Wash down motor 1/3HP, 115/230VAC 
single phase, 3450rpm, 56C, 60hz

 

CP12290

-

7

-

SS

 

Strainer Screen, 200 Mesh, SS

 

TE00TM4341

 

Sensor, temperature, RTD, 1/2" NPT, 150mm tip length, 

-

40...302F range, 316 

stainless steel, 4

-

pin micro DC connector

 

HT00BEN314S6C2

 

Heater, 3KW, 230VAC, 2 Alloy 800 elements, 304SS Nut (1

-

1/4 NPT), 15" Long.

 

VA00366FCSV

 

Valve, Manual, 2

-

Way, 1/2" 316SS.

 

VA0046495K23_AC01

 

Valve, Manual Ball Valve, 2

-

way, Threaded, Jacketed, 316SS.

 

VAXXEASSBBAFAF0_AC01

 

Valve, Manual Ball Valve, 3

-

way, Threaded, Jacketed, 316SS

 

VA007768K16

 

Check Valve, 1/4" NPT male x 1/4" NPT male, 1 PSI cracking pressure

 

VC00110

-

BC

 

1/4" Pressure Regulator, 1/4 NPT (female) End Plates, 0

-

100 PSI

 

VC003823T321

 

Regulator 

-

 Air/Water 

-

 For filling Heating Circuit 0

-

300 PSI INLET

 

VA008P014612C2_AC01

 

Ball Valve, 3

-

Way, Threaded, 316SS, Air Acctuated with Spring Return, Heated.

 

VC0098905K15

 

Valve, Safety Relief, 1/4" NPT, ASME poppet type, 304 stainless steel, 100 PSI

 

VC00BUDSSVTSS

 

Valve, Bushing, 1/2"NPTm X 3/8"NPTf connections, 316SS Body/Spring

 

Содержание AutoJet AccuCoat MV10

Страница 1: ...1 ML00MV10HTSYS spray com AccuCoat MV10 Heated System OWNER S MANUAL...

Страница 2: ...ew 5 3 1 Product Feature 5 3 2 System Specifications 6 3 3 Optional Add Ons 7 3 4 Spray Control Panel Options 8 4 System Hook Up 9 4 1 Connections 9 4 2 Watlow Controller 11 5 Operation 12 5 1 System...

Страница 3: ...orrectly ATTENTION Supplementary information for the user draws attention to possible problems SECTION 2 SAFETY 2 1 GENERAL SAFETY INFORMATION READ AND FOLLOW INSTRUCTIONS All safety related and opera...

Страница 4: ...NG Fluids under pressure can penetrate skin and cause severe injury ATTENTION Always remember to carefully read the chemical manufacturer s labels follow SDS and all directions WARNING OF SHOCK HAZARD...

Страница 5: ...ration An immersion heater maintains the temperature set point of the heated fluid and by extension the process fluid A pressure gauge high limit switch turns the heater off at 650 F for fail safe pro...

Страница 6: ...Humidity Range 5 to 95 non condensing Enclosures NEMA 4 Weight Control Panel tank skid 360lb empty Dimensions 58 H x 45 L x 35 D Level Switches TDR Time Domain Reflectometry Level Sensor 4 F to 302 F...

Страница 7: ...Supply Unit and requires a level sensor connection to attach to the control panel The level sensor displays the current tank level as a percent to full The refill setpoint can be adjusted for user pr...

Страница 8: ...nel 1000 is only capable with electric actuated spray nozzles and air nozzles can only work with a single channel Features AutoJet 1000 AutoJet 1750 AutoJet 2150 HMI Touch Screen 4 3 4 3 7 Power Input...

Страница 9: ...keted hose to the components at the base of the tank then exit at the top of the tank and returns to the standpipe This allows for air relief of the conditioning circuit at that connection When initia...

Страница 10: ...10...

Страница 11: ...to Refill on indicator when indicator is on Auto Refill is filling the tank Low Level indicator when indicator is on indicates the level in the tank is below the low level setpoint Heater controller u...

Страница 12: ...begin building pressure 9 Once the small yellow light on the sensor is lit allow the system to continue to fill for several minutes Wait until the inlet regulator at the top of the standpipe levels of...

Страница 13: ...ller on the front panel Once the system is filled and the condition ing fluid is circulating properly turn on the heater Wait until the system reaches the desired setpoint At this point the fluid has...

Страница 14: ...the tank has been initially filled and given the values in the above table as the system is being used the level in the tank will decrease Once the fluid reaches 250 mm from the bottom of the probe 63...

Страница 15: ...the PulsaJet gun s 6 Verify Trigger signal 7 Fluid may have solidified in supply lines reconfigure heating supply or increase temperature 8 Check nozzle for clogging 3 Conditioning Fluid pressure low...

Страница 16: ...ure if necessary Every 6 Months Tighten all screw terminal connections to insure proper bonding Every 12 Months Check component calibration and re calibrate if required See individual control componen...

Страница 17: ...gle phase 3450rpm 56C 60hz CP12290 7 SS Strainer Screen 200 Mesh SS TE00TM4341 Sensor temperature RTD 1 2 NPT 150mm tip length 40 302F range 316 stainless steel 4 pin micro DC connector HT00BEN314S6C2...

Страница 18: ...one 1 year on non wear parts from ship date Wear items are covered for manufacturing defect only for a period of one 1 year Wear items include but may not be limited to Liquid pump and Liquid regulat...

Отзывы: