SPLASH On Tap™                                    

Installation Guide 

40 Gallon Water Driven Proportioner (#40-SOTWD) 

 

Congratulations on your recent purchase of the SPLASH On Tap proportioner, the future of windshield 
washer fluid.  If you ever find that you need a replacement part you will be pleased to know that all 
parts are available at reasonable prices.

 

This package contains the following (DOES NOT INCLUDE A BACK-FLOW PREVENTER): 

1.

 

(1) 40-SOTWD Proportioner 

2.

 

(1) Windshield washer fluid hydrometer 

3.

 

(1) Magnetic snap action float  

4.

 

(1) Poly Float with chain 

5.

 

(4) Magnetic snap action float mounting screws 

6.

 

(1) Methanol quick connect 

7.

 

(1) Concentrate screen 

8.

 

(1) Metal wall bracket 
 

 

 

 

 

NOTICE: THE METHANOL BARREL MUST BE GROUNDED 

NOTICE: A back-flow preventer in compliance with local 
and/or state requirements must be installed on the water 
line to bring the unit to safety standards. 

8.

 

 (6) Tank bracket bolts 

9.

 

(6) Tank bracket washers 

10.

 

(4) 3/8” Lead anchors 

11.

 

(4) 3/8” Anchor screws 

12.

 

(4) Anchor washers 

13.

 

(1) Methanol hose 

14.

 

(2) Hose clamps 

15.

 

(1) Bung wrench 

Содержание On Tap

Страница 1: ...BACK FLOW PREVENTER 1 1 40 SOTWD Proportioner 2 1 Windshield washer fluid hydrometer 3 1 Magnetic snap action float 4 1 Poly Float with chain 5 4 Magnetic snap action float mounting screws 6 1 Methano...

Страница 2: ...omer is responsible for ensuring that he or she properly dilutes the methanol concentrate to be in compliance with all federal state local laws and regulations Although the manufacturer has attempted...

Страница 3: ...location of the unit measure and mark a level line 50 from the floor Detach metal wall bracket from the back of the unit Place the bottom of the metal bracket level with the line and mark the four mou...

Страница 4: ...l drum of methanol is grounded Wire and alligator clip is recommended Drill a 7 16 hole in the center of the concentrate spout cap Locate the concentrate hose inside the proportioner and through the t...

Страница 5: ...aded hole on the proportioner Step 5 Product Installation Locate the nearest water line Connect to the back of the magnetic float valve located on the top of the machine Use a line for this procedure...

Страница 6: ...setting valve 2 turns to the left and open the black on off valve Procedure 3 For a 20F product turn setting valve 4 turns to the left and open black on off valve Leave 1 on off valve open For a 32 F...

Страница 7: ...essure air 5 PSI Recommended through the hose to remove any build up If blowing the hose out does not solve the problem fully submerge the end of the hose and allow to soak for one hour in water or me...