Spirent B2-800-QD-4-T1S Installation Instructions
Technical Specifications
Spirent B2-800-QD-4-T1S Installation Instructions
|
7
PN 71-009377 Rev A May 2022
Technical Specifications
•
Environmental
•
Operating requirements: 50° to 95° F (10° to 35° C) when using QSFP-DD800
transceivers rated up to 15W of type 2A with a transceiver case temperature
thermal limit of 70C. When using QSFP-DD800 transceivers dissipating 30W of
type 2A with a thermal limit of 70C, the maximum operating temperature is 68° F
(20° C); 10% to 80% relative humidity (non-condensing). The minimum
operating temperature is 41 ° F (5° C).
Warning:
Use appropriate ear protection when working in proximity to an operating
chassis.
•
Chassis Design and Form Factor
•
EIA 19" rack compatible, 2RU high
•
Front to back airflow
•
Physical
•
Dimensions: 17.1"W x 3.5"H x 29.5"D (43.4 cm x 8.9 cm x 74.9 cm)
•
Unit installed weight: 53 lb. (24.0 kg)
•
Shipping weight: 66 lb. (29.94 kg)
•
Power
•
Two (2) power supplies
•
Inlet AC:
Two each of 110-127VAC @15A Nominal or 208-240VAC @10A
Nominal.
•
Peak power requirement: 2,000W per PSU
•
Administration and Operation
•
Up to 16 unique users per chassis
•
IPv4 and IPv6 admin network compatible
•
SSH terminal emulation via Ethernet
•
Direct via external video connector and USB ports