background image

1

OPERATING INSTRUCTIONS

7 Function Digital Autoranging Multimeter

DM6260

Slide Switch

A

A

400A

400A

AC/DC Voltage  
Measurement

˚F ˚C

°F°C  
Temperature Measurement

OFF

Power off

1.5V 

1.5V Battery Measurement 

Continuity / Resistance 
/ Diode Measurement

A

A

400A

400A

Read this owners manual thoroughly before use and save.

IMPORTANT: RECEIVING INSTRUCTIONS

   

Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. 
Shipping damage is NOT covered by warranty. The carrier is responsible for all repair or replacement costs resulting from damage in shipment.

1.0 DISPLAY FUNCTIONS & SYMBOLS

1.1 FUNCTIONS (Figure 1)

1. Display: Backlit 4000 Count LCD screen
2.  SELECT Button: Press to switch between AC voltage and DC voltage 

measurement functions, resistance, continuity, and diode measurement functions, 

and °F and °C measurement functions.

3.  HOLD / BACKLIGHT Button: Press to enter or exit the Data Hold mode. Press 

and hold to turn on the backlight. Press and hold again to turn off the backlight. 

The backlight will automatically turn off 1 minute after it is turned on.

4.  COM Terminal: Black test lead input jack common to all measurements.
5.  INPUT Terminal: Red test lead input jack for all measurements.
6.  Slide Switch: Slide to power the meter on and off and select the desired 

measurement function. To save battery power, turn to the 

“OFF”

 position when  

the meter is not in use. See 

“SLIDE SWITCH”

 section for function descriptions.

1.1  METER FUNCTIONS

Meter type:  

Auto

Display Count:  

4000

Battery:  

Requires 2 AAA batteries

Input impedance:  

10 Meg Ohm

AC Volt Ranges:  

4V, 40V, 400V, 600V, best accuracy (0.8%+5)

DC Volt Ranges:  

4V, 40V, 400V, and 600V, best accuracy (0.5%+3)

Temperature Ranges:  

-40˚F - 1832˚F (-40˚C - 1000˚C)

Resistance Ranges:  

 400ohm, 4kohm, 40kohm, 400kohm,  
4M ohm, and 20M ohm

Over Range Indication:    Displayed value > 4000 or the input  

measurement range, displays OL 

Polarity Indication:  

“-” is displayed for negative polarity

Agency Approvals:  

ETL, CE (IEC/EN61010:, CAT III 600V, Pollution Degree 2)

Operating Temperature:   32°F–104°F (0°C–40°C)

Relative Humidity:  

< 95%

Storage Temperature:  

-4°F–140°F (-10°- 50°C)

IP Degree:  

IP20

Dimension:   

142mm x 70mm x 25mm

Weight: 

Around 116g (without batteries)

Altitude:  

Maximum 2000m

Warranty Info:  

Limited lifetime warranty

1.2 DISPLAY SYMBOLS (Figure 2)

1. °F °C: Temperature Measurement
2. (M)(k) 

: Resistance Measurement

3. (m)V: Voltage Measurement
4. 

A

A

400A

400A

: Diode measurement

5. 

: Continuity Measurement

6. AUTO: Automatic power-off feature is enabled
7. 

 : The battery is low and must be replaced

8.   : The measuring voltage exceeds 30V AC/DC
9. AC: AC
10. 

1.8.8.8

Autorange

MAX MIN

AC
DC

 : Negative sign

11. DC: DC
12. 

1.8.8.8

Autorange

MAX MIN

AC
DC

 : Data Hold is enabled 

4

5

1

2

6

3

7

Figure 1

Figure 2

1

2

3

4

5

6

7

8
9

10

11
12

Отзывы: