Sperian MILLER Grip 497 Скачать руководство пользователя страница 1

Spring 

Stop Sleeve 

Return Wire  

Cleaning Bushing 

Spoons 

Galvanized Thimble 

Swag

Trigger 

Main Cable 

Wire Guide 

Conical End Fitting 

Miller Fall Protection    

PH: 1-800-873-5242    FX: 1-800-892-4078     www.millerfallprotection.com

 

1” Miller Grip Anchorage 

WARNING!!  

All persons using this equipment must read and  
understand all instructions. Failure to do so may 
result in serious injury or death. If a fall occurs, 
the Miller Grip must be disposed of according to 
the manufacturer’s instruction. 

IMPORTANT!! 

Users should be familiar with pertinent regulations 
governing this equipment. All individuals who use 
this product must be correctly instructed on how to 
use this device. 

Operations and Instruction Manual 

Miller Grip Anchorage - Model #497 

Portable Concrete Anchorage Connector 

ANSI Z359.1  10,000 lbs / 44kn 

Manufactured Aug, 2007.  Batch #033 

1.  Follow all manufacturer’s instructions. 
2.  Use only locking snap hooks or locking carabiners. 
3.  Always inspect your units prior to use. 
4.  Use the proper method of coupling to anchorage. 
5.  Always dispose of this unit after a fall has occurred.  
6.  Patch all holes with concrete when job is complete. 
7.  Pregnant women and minors must not use this product. 
8.  Designed safe working load is 2,000 lbs ( 8.8 KN ). Do not exceed this  
       weight when you pretension your Life Line System. 

 

1” Miller Grip 

 

 

 

T

ested  -                  ANSI  Z359.1  

 

 

 

Strength - 

 10,000 lbs / 44 KN   

   

 

 

Model  -                   Miller Grip  #497 

Color Coded  Green Thimble

 

Miller’s 1” Fall Protection Miller Grips are to be used in concrete  

substrate only. DO NOT use in steel, wood or any other substrate.   

Miller Grips can be placed in: 

 

* Horizontal surfaces 

 

 

* Horizontal Life Lines 

* Vertical surfaces 

 

 

* Vertical life Line 

* Overhead / ceiling surfaces 

 

 

This product is to be used by qualified fall protection  
personnel only.  It is to be anchored in accordance with 
manufacturer’s requirements in concrete substrate only. 
Do not anchor in uncured/wet concrete.  
 
The model Miller Grip #497 is color coded with a green 
thimble, and is used for 

FALL PROTECTION ONLY

. This 

unit is not to be used in any other anchoring situation. 
Concrete must have a compressive strength of at least 
3,000 PSI (20.7MPa) 

 

Made in the USA 

Отзывы: