70
Brewing problem
Troubleshooting
Wort fontains shoot up
when circulating
Malt is too finely ground. Grind the malt
yourself if necessary
Pump clogged
Insert the fine screen / filter cloth and
screen plate more thoroughly. Pour the
malt more carefully into the malt pipe. The
malt must not fall into the boiler!
Pump makes noise
The pump seal is too strong tightened
(hand tight is sufficient) or not properly
vented. Clean if necessary.
Temperature start-up
time is very long
Put the lid on during heating. Place the
Braumeister sheltered from the wind.
Condensation water
leaks out of the lid
Set up Braumeister horizontally.
Circulation process
does not get going
Check that the pump is working and
that it is vented. Check that the malt pipe
and seal with gasket are evenly
distributed.
Wort flows off too slowly
or not at all during lau-
tering
Prick several times with a wooden spoon
from the top to the lower sieve plate.
Malt is too finely ground. Only break up the
grains, not grind them finely.
7.2 Troubleshooting
Do not repair the appliance yourself, but consult an authorised technici-
an. To avoid any hazards, a defective control unit / mains cable or other
electrical components may only be replaced or repaired by the manufac-
turer, our customer service or a similarly qualified person.
BREWING MISTAKES
Содержание 41000-20
Страница 2: ......
Страница 6: ...Item no 46500 20 Braumeister 500 litres...
Страница 16: ...The pump pressure control screen Overview of the start screen You find the pump speed under the tab marked P...
Страница 18: ...Determination of the desired water level The screen for filling water...
Страница 20: ......
Страница 21: ...21 20...
Страница 32: ...In the Settings section you will find options for setting language Wi Fi metrics sound etc Settings...
Страница 44: ...Mashing process Pour in malt measurements refer to a 20 litres Braumeister...
Страница 67: ...67 66...
Страница 73: ...73 72...
Страница 79: ...79 78...