background image

bar

psi

bar

psi

1

5

7

8

3

EFHS INSTALLATION & OPERATION GUIDE

Installation should be carried out by a competent person with previous plumbing experience. 

All installations should comply with local bylaws. 

Equipment Supplied 

Housing System

1.  

Pressure gauges 

(single - 2 /double - 3/triple - 4)

2.  

Pressure Release Valve (PRV)

3.  

Housing bracket

4.           EFH-(PK or SC) plastic housing

Accessories

5.  

1 x Housing spanner

6.  

1 x Wall mounting screw kit

7. 

1 x SPECTRUM brand label

8.

 

1 x Cartridge replacement label

Note:

 Double and Triple Systems include connecting nipples.

9.           Fittings Kit 

Before starting, shut off the water supply to the location where the 

unit is to be installed. Clear the location of any hazards, ie electrical.

 
1.  Using the housing bracket, mark out the location for affixing the 

system, ensuring a minimum 1½" clearance at the base for bowl 
removal (required for filter cartridge replacement).  

2.  Remove the bowl(s) to make installation easier.
3.  Affix to the mounting surface.

NOTE:

 Screws supplied are not suitable for all mounting surfaces. Use 

details in Table 1 to work out the correct fixing option.
4.  Unwrap and insert cartridge(s) into bowl(s) as required (coarser 

filters first). Refit bowl(s) onto the housing head(s) and hand 
tighten, ensure cartridges are sealed correctly and seal against the 
head. Use the spanner to tighten bowl, follow the arrow moulded 
on spanner handle.

5.  Turn the water back on and depress the blue pressure release 

valve to purge any air.

6.  Check for leaks around system.
7.  Run the system until the filter(s) has been flushed thoroughly 

(approx. 5 litres).

8.  Check for leaks before leaving the system in operation. Use 

spanner to tighten bowl (if required).

6

*Weights based on use with water and appropriate sized cartridges. 
System weights with other fluids will vary. 

bar

psi

SPECTRUM EFHS Installation & Replacement Cartridge Instructions0821v2

Please note : Systems left unused for extended periods of time should be fully flushed to drain before using.

4

TABLE 1. 

 

GUIDELINE WET SYSTEM WEIGHT W/O CARTRIDGE

HOUSING 

SIZE

PORT SIZE

"

WET WEIGHT 

KG*

SINGLE

10

1/4 & 3/8

3.0

20

1/2 & 3/4

5.0

10LD

1

8

20LD

1

14

DOUBLE

10

1/4 & 3/8

6.0

20

1/2 & 3/4

10

10LD

1

16

20LD

1

28

TRIPLE

10

1/2 & 3/4

8.5

20

1/2 & 3/4

16

10LD

1

24

20LD

1

42

9

2

“Example system shown is Part Number : EFHS-PK/PK-10-3/4”

Отзывы: