Страница 1: ...SPECTRUM D101 X P3807 BD Series Explosion Proof Network Camera Installation Manual D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 1 ...

Страница 2: ...Thispageintentionallyleftblank 2 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Страница 3: ... Solutions LLC acknowledges all trademark s and the rights of the trademark s owned by the company referred to herein Release Date 02 05 2020 Document Name D101 A P3807 PVE BD Copyright 2019 by Spectrum Camera Solutions LLC All rights reserved Revision Record Rev Description Date 0 Initial Release 07 23 2020 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 3 ...

Страница 4: ...rcising maximum possible legal action against all persons and or organizations involved Disclaimer Spectrum Camera Solutions LLC makes no representations or warranties with respect to the contents hereof Further Spectrum Camera Solutions LLC reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such revisi...

Страница 5: ...ANUAL REV 1 5 Page DESCRIPTION 6 MODEL MATRIX 7 LABELS 8 STANDARDS AND CERTIFICATIONS 9 DOCUMENT SYMBOLS 10 HOW TO USE THIS MANUAL 11 GENERAL SAFETY AND OPERATING INFORMATION 12 SPECIFICATIONS 15 UNBOXING 17 HARDWARE BOM 18 WIRING ENTRIES 19 INSTALLATION 20 DIMENTIONAL GENERAL ASSEMBLY 25 DISMANTLING MAINTENANCE 26 MOUNTING OPTIONS 28 ...

Страница 6: ...e need for extra equipment reduces installation time reduces labor expenses and increases safety by lessening the potential for mismatched hazardous rated components Additionally the D Series are constructed with a proprietary explosion resistant polymer blend offering maximum clarity and enhance optical performance To enhance optical performance the explosion proof lens is equipped with our Virtu...

Страница 7: ...ing 1 S Stainless Steel 316L Housing C Internal Equipment Part Number from Manufacturer BD Optional Breather drain model Internal components and D Series must be approved by Spectrum Internal Equipment Manufacturer Code below Must be approved and verified by Spectrum Models supplied with Breather Drains will have IP66 ingress protection level CODE XX Manufacture 01 AXIS COMMUNICATIONS D101 A P3807...

Страница 8: ...Labels Option A 8 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 BREATHER DRAIN MODEL BREATHER DRAIN MODEL ...

Страница 9: ...manufacturer if dimensional information on the flameproof joints is necessary Follow the manufacturer s instructions to reduce the potential of an electrostatic charging hazard on the surface of the equipment in Group II and III environments The equipment meets the requirements according to the low level risk of mechanical danger Therefore the equipment shall be located and installed such that the...

Страница 10: ... of electric shock or high temperature parts may result in injury if proper precautions are not taken NOTE Emphasizes important or essential information Locating Information NOTE In the interest of completeness manuals and drawings included with the system may provide information pertaining to options not included with your equipment Information in application notes supersedes general information ...

Страница 11: ...ficates for any Special Conditions of Use If the sign X is placed after the certificate number it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule of the certificate NOTE Review all material and safety information in this manual and install in accordance with this document and all other applicable ATEX CSA IECEx NEC NFPA70 In...

Страница 12: ...g and servicing any part of electrical equipment Hot components should be allowed to cool before servicing if possible Other appropriate equipment or clothing must be used as required by the type of work performed All applicable regulations and procedures must be followed for the work performed Before beginning any work on the equipment carefully consider all the potential hazards and ensure that ...

Страница 13: ...ON The electrical cover should never be removed unless power is removed for at least 5 minutes from the unit or the area is known not to contain explosive materials 13 WARNING The product shall be installed by a trained professional The product shall be used in compliance with local laws and regulations Store the product in a dry and ventilated environment Avoid exposing the product to impacts sho...

Страница 14: ...roperties of terminal housing compartment The connection to the external circuits must be realized by cable glands or pipe fittings covered by a separate certificate s If a cable gland is not used or an entry is open the entry must be closed by a stopping plug covered by a separate certificate The diameter of the cable gland is cylindrical ISO M20 x 1 5 This equipment can be used with different vo...

Страница 15: ...0 C to 55 C Type 4X IP66 Class II III Division 1 Groups E F G T6 Type 4X IP66 Ta 20 C to 55 C Class I Zone 1 AEx Ex db IIB H2 T6 Gb Ta 20 C to 55 C Type 4X IP66 Zone 21 AEx Ex tb IIIC T85 C Db Ta 20 C to 55 C Type 4X IP66 CERT NO FM18ATEX0057X IECEx FMG 18 0020X II 2 G Ex db IIB H2 T6 Gb Ta 20 C to 55 C IP66 II 2 D Ex tb IIIC T85 C Db Ta 20 C to 55 C IP66 Electrical Requirements D101 A P3807 PVE B...

Страница 16: ...ts products or attached products 16 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 SPECIFICATIONS D101 X P3807 PVE BD Series Casing Material Specifications S 316L STAINLESS STEEL 47lbs A ANODIZED ALUMINUM 19lbs D101 X P3807 PVE BD Explosion Proof Camera Hazardous Area Voltage Material Model Number IEEE 802 3af at Type 2 Class 4 PoE Midspans PoE Injectors 316L STAINLESS S...

Страница 17: ...Remove hardware 4 Install ring Gasket on terminal Housing Optional SD GK Aluminum version only 5 Install wall mount with hardware removed from step 3 Note Apply Anti seize to bolts 6 Install wall mount gasket and hardware to secure mount to wall SD GK 7 Remove foam and protective blue film Note Apply Anti seize to bolts Optional SD GK Anti Galvanic corrosion isolation gasket kit for offshore use o...

Страница 18: ... D SERIES INSTALLATION MANUAL REV 1 HARDWARE BOM 4 1 3 2 5 1 QTY 1 EXTERNAL GROUND LUG 2 QTY 3 M10 X 1 5 18 8 BOLT 3 4 SETS WEDGE LOCK WASHER 4 QTY 1 D2005 Z CLIP 5 SD WM WALL MNT NOT INCLUDED 6 M10X1 25 M10X1 5 ADAPTER 7 M10x1 25 hex nut 6 7 ...

Страница 19: ...ALLATION MANUAL REV 1 WIRING ENTRIES Conduit Entries are M20 x 1 5 Use appropriate adapter with nylon Washer or O ring to keep ingress protection level CAUTION Ensure the Ethernet cable is disconnected from power source prior to wiring to the terminal block ...

Страница 20: ... 2 Make sure threads on camera and M10x 1 5 are free of dirt and debris Place mount on camera and align holes and tighten bolts add anti seize for offshore installation 3 Attach the camera with wall mount to mounting surface Use only installation methods and materials capable of supporting four times the maximum specified load of the system D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLAT...

Страница 21: ...on box through user supplied cable gland and seal using the recommended gland installation practices D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 Figure 2 Removing D1005 cap Conduit Entries are M20 x 1 5 Use appropriate Adapter with Nylon Washer or O ring to keep ingress protection follow guidelines of the manufacturer of gland or adapter INSTALLATION ...

Страница 22: ... Position 2 Orange Position 3 White Green Position 4 Blue Position 5 White Blue Position 6 Green Position 7 White Brown Position 8 Brown Table 1 Figure 5 Wire Cable Connections INSTALLATION External Ground Internal Ground Figure 6 Grounding 8 Connect ground to equipment before powering For U S zones the internal grounding connection shall be used and the external grounding connection shall be a su...

Страница 23: ...h Nylon Washer or O ring to keep ingress protection D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 INSTALLATION CAUTION Ensure the ethernet cable is disconnected from power source prior to wiring to the terminal block Figure 3 Figure 4 ...

Страница 24: ... SERIES INSTALLATION MANUAL REV 1 Figure 7 Installing D1005 cap Figure 8 Retaining clip order Figure 9 Final assembly INSTALLATION NOTE Do not install camera unless power is applied in near future 12 Remove protective film after installation If protective film is not removed in timely manor damage to dome is likely to occur with UV exposure 13 Apply power For internal equipment startup procedures ...

Страница 25: ...Dimensional General Assembly 25 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Страница 26: ...sh soap and water Lastly apply coating of Repel by Unelko corporation surface cleaner Never use harsh chemicals or abrasive towels Replacing the battery The Axis Q6075 E product uses a 3 0 V BR2032 lithium battery Lithium primary battery composed of cathode from carbon monofluoride anode from lithium and electrolyte from organic solvent and lithium salt as the power supply for its internal real ti...

Страница 27: ...pectrum Camera Solutions declares that under our sole responsibility that the product s listed below conform to the relevant provisions of 2014 34 EU Doc No Dxx 100107152019 2014 34 EU D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 27 ...

Страница 28: ...SD WM WALL MOUNT 28 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Страница 29: ...SD HM WALL MOUNT 29 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 WEIGHT 7 LBS ...

Страница 30: ...SD PMA POLE MOUNT ADAPTER 30 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 M12 1 75 18 8 Bolts QTY 2 12in all thread with nuts and washers QTY 2 A1612 sides ...

Страница 31: ...SD CM CORNER MOUNT 31 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 16 20 18 8 Bolts ...

Страница 32: ...SD VM VIBRATION MOUNT 32 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 16 20 18 8 Bolts FRONT ...

Страница 33: ...ASSEMBLY MOUNTS 33 D101 A P3807 PVE BD REV 0 105607312018 D SERIES INSTALLATION MANUAL REV 1 SD CM SD PMA SD CM SD VM SD SO SD PMA ...